Omron GRT1-ML2 Hardware Reference Manual page 161

Trajexia motion control system
Hide thumbs Also See for GRT1-ML2:
Table of Contents

Advertisement

Hardware reference
Replace
Caution
The GRT1-ML2 is a unit that is part of a network. If the GRT1-ML2
is damaged, it effects the whole network. Make sure that a dam-
aged GRT1-ML2 is repaired immediately.
To replace the unit, follow these rules:
Turn off the power before replacing the unit. This includes the power to
all master and slave units in the network.
Make sure that the new unit is not damaged.
If a poor connection is the probable cause of any malfunctioning, do
these steps:
-
Clean the connectors with a clean, soft cloth and industrial-grade
alcohol.
-
Remove any lint or threads left from the cloth.
-
Install the unit again.
When returning a damaged unit to the OMRON dealer, include a detailed
damage report with the unit.
Before reconnecting the new unit, do these steps:
-
Set the MECHATROLINK-II station address to the same address as
the old unit.
-
If the table registration function was used for the old unit, create a
new registration table for the new unit. See the Trajexia
Programming Manual.
3.6.4
Online replacement
It is possible to replace SmartSlice I/O Units connected to a GRT1-ML2
when the power is on. The I/O communication continues while a SmartSlice
I/O Unit is removed and replaced.
To replace a SmartSlice I/O Unit online, do these steps:
1. Turn off all power supplies of the SmartSlice I/O Unit. This is the I/O
power supply, plus possible external power supplies to the terminal block
(for example, a Relay Output Unit).
2. Release the locks on the front of the unit and remove the terminal block.
Do not remove the wiring.