Hardware reference
MECHATROLINK-II connectors (CN6A & CN6B)
Connect the G-series Servo Driver to the MECHATROLINK-II network using
the CN6A and CN6B connectors. Use one of the MECHATROLINK-II
connectors to connect to the previous MECHATROLINK-II device or the
TJ1-ML__. Use the other MECHATROLINK-II connector to connect to the
next MECHATROLINK-II device, or to connect a MECHATROLINK-II
terminator.
Note
Cable length between nodes (L1, L2, ... Ln) should be 0.5 m or
longer.
Total cable length should be L1 + L2 + ... + Ln = 50 m max.
HARDWARE REFERENCE MANUAL
fig. 61
MC Unit
L1
L2
Ln
Termination
resistor