Allocating I/O from the Configurator
Leave the field blank for unit numbers that are not allocated to Temperature
Controller.
Note
Click the Set Button beside the unit number to display the Edit Unit
Parameters Window and then edit the parameters of the corre-
sponding Temperature Controller (refer to page 78). Click the Op-
eration Button to display the Operation Commands for Units
Window, and control the corresponding Temperature Controller (re-
fer to page 77).
Click the Copy Button to copy parameters between Temperature
Controllers simply by specifying the copy source and destination.
(refer to page 75).
4. Create Allocation Data for the OUT Area
Create the allocation data for the OUT Area in the I/O Allocations (OUT)
Tab Page. Select the data to be allocated from the list in the Parameters
field (top half of window), and drag the corresponding word to one of the
Allocation Areas (bottom half of window).
Alternatively, select the parameter to be allocated and click the Allocate
Button to display the I/O Allocations Dialog Box. Specify the allocation des-
tination and click the OK Button.
Note a) The number of words from the first word is shown as +@, where
the box indicates the number.
Section 4-3
47