Simple I/O Allocation
Data Allocated in the
OUT Area
42
Address
First word + 35 words
First word + 36 words
First word + 37 words
First word + 38 words
First word + 39 words
First word + 40 words
First word + 41 words
First word + 42 words
First word + 43 words
First word + 44 words
First word + 45 words
Note
1. Individual bits will be enabled only through those for the maximum number
of connected Temperature Controllers set on the rear panel rotary switch.
2. Words will be allocated only through those for the maximum number of
connected Temperature Controllers.
Example:
If the maximum number of connected Temperature Controllers is 10, then
the allocated IN Area will be the 36 words, i.e., from the first word to the
first word + 35 words.
The following table shows the configuration of the OUT Area when simple I/O
allocation is used.
Address
First word + 0 words
First word + 1 words
First word + 2 words
First word + 3 words
First word + 4 words
First word + 5 words
First word + 6 words
First word + 7 words
First word + 8 words
First word + 9 words
First word + 10 words
First word + 11 words
First word + 12 words
First word + 13 words
First word + 14 words
First word + 15 words
First word + 16 words
First word + 17 words
First word + 18 words
First word + 19 words
First word + 20 words
First word + 21 words
First word + 22 words
First word + 23 words
First word + 24 words
Unit 10, Ch2 PV (type number 100) (See note 2.)
Unit 11, Ch1 PV (type number 100) (See note 2.)
Unit 11, Ch2 PV (type number 100) (See note 2.)
Unit 12, Ch1 PV (type number 100) (See note 2.)
Unit 12, Ch2 PV (type number 100) (See note 2.)
Unit 13, Ch1 PV (type number 100) (See note 2.)
Unit 13, Ch2 PV (type number 100) (See note 2.)
Unit 14, Ch1 PV (type number 100) (See note 2.)
Unit 14, Ch2 PV (type number 100) (See note 2.)
Unit 15, Ch1 PV (type number 100) (See note 2.)
Unit 15, Ch2 PV (type number 100) (See note 2.)
Output Enable Bits Units 0 to 7 (See note 1.)
Output Enable Bits Units 8 to 15 (See note 1.)
RUN/STOP Units 0 to 7 (See note 1.)
RUN/STOP Units 8 to 15 (See note 1.)
AT execute/cancel Units 0 to 7 (See note 1.)
AT execute/cancel Units 8 to 15 (See note 1.)
Unit 0, Ch1 SP (type number 123) (See note 2.)
Unit 0, Ch2 SP (type number 123) (See note 2.)
Unit 1, Ch1 SP (type number 123) (See note 2.)
Unit 1, Ch2 SP (type number 123) (See note 2.)
Unit 2, Ch1 SP (type number 123) (See note 2.)
Unit 2, Ch2 SP (type number 123) (See note 2.)
Unit 3, Ch1 SP (type number 123) (See note 2.)
Unit 3, Ch2 SP (type number 123) (See note 2.)
Unit 4, Ch1 SP (type number 123) (See note 2.)
Unit 4, Ch2 SP (type number 123) (See note 2.)
Unit 5, Ch1 SP (type number 123) (See note 2.)
Unit 5, Ch2 SP (type number 123) (See note 2.)
Unit 6, Ch1 SP (type number 123) (See note 2.)
Unit 6, Ch2 SP (type number 123) (See note 2.)
Unit 7, Ch1 SP (type number 123) (See note 2.)
Unit 7, Ch2 SP (type number 123) (See note 2.)
Unit 8, Ch1 SP (type number 123) (See note 2.)
Unit 8, Ch2 SP (type number 123) (See note 2.)
Unit 9, Ch1 SP (type number 123) (See note 2.)
Section 4-2
Item
Item