Restrictions on Reading Total ON Time/Contact Operation Counter for All Slaves at Once
Reading from the Configurator
Select the uploaded Unit using the Configurator, click the right mouse button over the Unit, and select Prop-
erty. The value displayed in the Revision field of the Property Window is the identity software version.
Reading Monitor Status for Each Terminal
For models that do not support the Monitor Status for Total ON Time or Contact Operation Monitor for All
Slaves Read at Once command, read the monitor status for Total ON Time or Contact Operation Monitor for
each terminal separately.
Reading Each Terminal
Reading input terminals
Reading output terminals
Converting Data Read for Each Terminal into Data for All Slaves
The data read for each individual terminal can be processed automatically using a ladder program as a batch
of data for all Slaves. Use the following method to read the data for all Slaves when using a product with manu-
facturer revision 1.01. The method shown here reads the data separately for each terminal and then converts
the data into data read as a batch for all Slaves.
540
Read using the Attribute ID 67 Hex, as described under Setting and Monitoring the
Terminal (Input) on page 471.
Read using the Attribute ID 67 Hex, as described under Setting and Monitoring the
Terminal (Output) on page 472.