Omron DRT2 SERIES DEVICENET SLAVES - OPERATION MANUAL 04-2008 Operation Manual page 351

Devicenet slaves
Hide thumbs Also See for DRT2 SERIES DEVICENET SLAVES - OPERATION MANUAL 04-2008:
Table of Contents

Advertisement

Analog Input Terminals
Analog Data 2 (Instance
114)
Generic Status Flags
(Instance 121)
330
The data format used for allocating data in the Master is shown below. Data is
allocated as two's complements (8 bytes = 4 words).
15
Analog Data 2 is used to monitor other analog data in addition to that in Ana-
log Data 1. Select one type of following data other than that allocated for Ana-
log Data 1: Analog input value, peak value, bottom value, top value, valley
value, or rate of change.
Note The comparator function cannot be used with Analog Data 2.
The data format used for allocating data in the Master is shown below. Data is
allocated as two's complements (8 bytes = 4 words).
15
The Generic Status Flags are used to monitor flags that indicate maintenance
information (Network Power Voltage Monitor Flag, Unit Conduction Time Mon-
itor Flag, and Analog Cumulative Counter Flag). The following data format is
used for allocating flags in the Master (1 byte).
Bit 7
Bit 6
0
0
The details of each bit are shown in the following table.
Bit
Abbrevia-
tion
0
---
1
---
2
NPW
3
RHW
4
CCW
5
MRF
6
---
7
---
The following format is used when Generic Status Flags are allocated, start-
ing from the rightmost byte of the Master.
Word 15
Analog Data 1 for Input 0
Analog Data 1 for Input 1
Analog Data 1 for Input 2
Analog Data 1 for Input 3
Analog Data 2 for Input 0
Analog Data 2 for Input 1
Analog Data 2 for Input 2
Analog Data 2 for Input 3
Bit 5
Bit 4
MRF
CCW
Name
---
---
Network Power Voltage Mon-
itor Flag
Unit Conduction Time Moni-
tor Flag
Analog Cumulative Counter
Flag
Unit Error Flag
---
---
+0
Section 7-4
0
0
Bit 3
Bit 2
Bit 1
RHW
NPW
0
Details
Reserved. (Always 0.)
Reserved. (Always 0.)
Turns ON when the Network
power level drops below the
set monitor value.
Turns ON when the Unit ON
time exceeds the set monitor
value.
Turns ON when any of the
cumulated analog values
exceeds the set monitor
value.
Turns ON when analog con-
version stops due to a Unit
error.
Reserved. (Always 0.)
Reserved. (Always 0.)
8
7
Generic Status Flags
Bit 0
0
0