Omron DRT2 SERIES DEVICENET SLAVES - OPERATION MANUAL 04-2008 Operation Manual page 316

Devicenet slaves
Hide thumbs Also See for DRT2 SERIES DEVICENET SLAVES - OPERATION MANUAL 04-2008:
Table of Contents

Advertisement

Overview of Analog Slaves
Slave
Unit power supply
Communications power sup-
ply current consumption
Connections
Data allocated in Master
Node address setting
Baud rate setting
Moving average
Off-wire (disconnection)
detection
Scaling, offset compensation,
peak/bottom hold, top/valley
hold, rate of change opera-
tions, comparator
Mainte-
User adjustment
nance
Cumulative counter
functions
Last maintenance
date
Input temperature
variation detection
function
Temperature inte-
gration function
Top/Valley count
function
Temperature range
timing function
7-1-3
List of Data Processing Functions
DRT2-AD04/DRT2-AD04H Analog Input Terminals
Function
Moving average
Setting the number of AD
conversion points
(DRT2-AD04 only)
DRT1 Series
Supplied by local power supply terminal.
30 mA max.
Poll, Bitstrobe
Just temperature data for 4 inputs
Set using the DIP switch.
Set using the DIP switch.
Not supported.
Supported.
Not supported.
Note The input accuracy depends on the mounting method. For details, refer to the
Performance Specifications in 7-6-1 DRT2-TS04T and DRT2-TS04P Temper-
ature Input Terminals.
The following tables list the data processing functions that can be used with
Analog Slaves. Refer to 7-4-3 Functions and Settings for details on functions
and setting methods.
Calculates the average of the past eight analog input val-
ues, and produces a stable input value even when the input
value is unsteady.
By reducing the number of input conversion points, the con-
version cycle speed can be increased. For details, refer to
7-4-4 Calculating the Conversion Cycle (DRT2-AD04 Only).
Supplied by communications power supply.
70 mA max.
Poll, Bitstrobe, COS/cyclic
Default: Temperature data for 4 inputs
The following data items can be allocated
by making additional Configurator settings:
Peak value, Bottom value, Top value, Valley
value, Rate-of-change value, Comparator
result; Generic Status Flags, etc.
Set using the rotary switches or the Config-
urator.
Automatically detected: Uses the baud rate
set for the Master Unit.
Supported. (Set using Configurator.)
Supported. (Set using Configurator.)
Details
Section 7-1
DRT2 Series
Default
Moving average disabled.
4-point conversion
295

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Devicenet drt2-id08Devicenet drt2-id08-1Devicenet drt2-id16-1Devicenet drt2-od16Devicenet drt2-od08Devicenet drt2-md16 ... Show all

Table of Contents