Temperature Input Terminals
Dimensions
7-6-3
I/O Data Selection and Allocation
Selecting
Temperature Data
Using the Configurator
1,2,3...
115
Up to two of the six resulting values can be selected to allocate in the Master
(one type each for Temperature Data 1 and Temperature Data 2). Select from
analog input value, peak value, bottom value, top value, valley value, and rate
of change. The selected data is allocated in the Master individually or in com-
bination with Status Flags. The following methods can be used to select the
temperature data.
1. Double-click the icon of the Slave to be set in the Main Window and open
the Edit Device Parameters Window. (From the Maintenance Mode Win-
dow, click the right mouse button over the Slave icon and select Parame-
ters and Edit.)
2. Click the Tab Page for the input where temperature data is to be selected.
From the data on which math operations have been performed, select two
types of data from the pull-down menu as Temperature Data 1 and Tem-
perature Data 2.
3. Return to the General Tab, click the Download Button, and then click the
Reset Button to reset the Unit.
4. Click the OK Button and exit the window.
Section 7-6
43.9
29.9
49.7
393