4.3.10.2 Loop Protection Status

This page displays the loop protection port status of the switch; screen in
The page includes the following fields:
Object
 Port
 Action
 Transmit
 Loops
 Status
 Loop
 Time of Last Loop
Description
The switch port number of the port.
Controls whether loop protection is enabled on this switch port.
Configures the action performed when a loop is detected on a port. Valid values
are Shutdown Port, Shutdown Port and Log or Log Only.
Controls whether the port is actively generating loop protection PDU's, or
whether it is just passively looking for looped PDU's.
Figure 4-3-10-2: Loop Protection Status Screenshot
Description
The Industrial Managed Switch port number of the logical port.
The currently configured port action.
The currently configured port transmit mode.
The number of loops detected on this port.
The current loop protection status of the port.
Whether a loop is currently detected on the port.
The time of the last loop event detected.