4.6.1.3 Ethernet Ring Protocol Switch

The Ethernet Ring Protection Switch instances are configured here; screen in
The page includes the following fields:
Object
 Delete
 Port 0
 Port 1
 Port 0 SF MEP
 Port 1 SF MEP
 Port 0 APS MEP
 Port 1 APS MEP
 Ring Type
 Major Ring ID
 Alarm
Buttons
Figure 4-6-1-3: Ethernet Ring Protocol Switch page screenshot
Description
This box is used to mark an ERPS for deletion in next Save operation.
This will create a Port 0 of the switch in the ring.
This will create "Port 1" of the switch in the Ring. As interconnected sub-ring will
have only one ring port, "Port 1" is configured as "0" for interconnected sub-ring.
"0" in this field indicates that no "Port 1" is associated with this instance
The Port 0 Signal Fail reporting MEP.
The Port 1 Signal Fail reporting MEP. As only one SF MEP is associated with
interconnected sub-ring without virtual channel, it is configured as "0" for such
ring instances. "0" in this field indicates that no Port 1 SF MEP is associated with
this instance.
The Port 0 APS PDU handling MEP.
The Port 1 APS PDU handling MEP. As only one APS MEP is associated with
interconnected sub-ring without virtual channel, it is configured as "0" for such
ring instances. "0" in this field indicates that no Port 1 APS MEP is associated
with this instance.
Type of Protecting ring. It can be either major ring or sub-ring.
Major ring group ID for the interconnected sub-ring. It is used to send topology
change updates on major ring. If ring is major, this value is same as the
protection group ID of this ring.
There is an active alarm on the ERPS.