Summary of Contents for ABB Terra AC

  • Page 1 User manual Terra AC © Copyright 2020 ABB. All rights reserved...
  • Page 2 Copyright All rights to copyrights, registered trademarks, and trademarks reside with their respective owners. ® Copyright ABB EV Infrastructure. All rights reserved. BCM.V3Y00.0-EN | 001...
  • Page 3: Table Of Contents

    Contents Contents About this document................6 Function of this document....................6 Target group........................6 Revision history........................6 Language..........................6 Illustrations......................... 6 Units of measurement......................6 Typographical conventions....................6 How to use this document....................6 General symbols and signal words..................7 1.10 Special symbols for warnings and dangers................ 8 1.11 Related documents......................8 1.12...
  • Page 4 Contents Safety instructions for use....................20 Safety instructions during cleaning or maintenance............21 Signs on the EVSE......................21 Discard parts or the EVSE....................22 Operation.................... 23 Prepare before use......................23 Energize the EVSE......................23 Connect the EVSE with the mobile app................23 Start a charge session......................24 4.4.1 EVSE with an EV charge cable.................
  • Page 5 Contents 7.7.1 AC output specifications (Europe)..............38 7.7.2 AC output specifications (North America)............38 Specific power consumption specifications..............38 Cleaning specifications.....................38 BCM.V3Y00.0-EN | 001...
  • Page 6: About This Document

    About this document About this document Function of this document The document is only applicable for this EVSE (Terra AC), including the variants and options listed in section The document gives the information that is necessary to do these tasks: •...
  • Page 7: General Symbols And Signal Words

    About this document General symbols and signal words Signal word Description Symbol Danger If you do not obey the instruction, this can Refer to section 1.10 cause injury or death. Warning If you do not obey the instruction, this can Refer to section 1.10 cause injury.
  • Page 8: Special Symbols For Warnings And Dangers

    Manufacturer and contact data Manufacturer ABB EV Infrastructure Heertjeslaan 6 2629 JG Delft The Netherlands Contact data The local representative of the manufacturer can give you support on the EVSE. You can find the contact data here: https://new.abb.com/ BCM.V3Y00.0-EN | 001...
  • Page 9: Abbreviations

    About this document 1.13 Abbreviations Abbreviation Definition Alternating current Controller area network Central processing unit Direct current Electromagnetic compatibility Electric vehicle EVSE Electric vehicle supply equipment Measuring Instruments Directive Near field communication NoBo Notified body OCPP Open charge point protocol Protective earth Personal protective equipment RFID...
  • Page 10: Orientation Agreements

    About this document Note: It is possible that not all terms are present in this document. 1.15 Orientation agreements Front side: face forward to the EVSE X-direction (positive is to the right) during normal use Y-direction (positive is rearward) Left side Z-direction (positive is upward) Right side Rear side...
  • Page 11: Description

    Description Short description The EVSE (Terra AC) is an AC charging station that you can use to supply electricity to an EV. The Terra AC offers tailor-made, intelligent and network charging solutions for your company or home. The EVSE can connect to the internet via GSM, WiFi or LAN.
  • Page 12: Overview

    Description Manufacturer MiD mark and Nobo number Serial number MiD accuracy class Part number of the EVSE MiD type examination number Product name Barcode with the serial number of the EVSE rating information EVSE Address of the manufacturer Barcode with the part number of the CE mark EVSE Ingress protection rating date of the...
  • Page 13: Overview Of The Evse, Outside

    Description Part Function EV charge cable To conduct the charge from the EVSE to the EV The EV of which the batteries need to be charged Parking space Location for the EV during the charge ses- sion RFID card or smartphone To authorize the user to use the EVSE 2.4.2 Overview of the EVSE, outside...
  • Page 14: Overview Of The Evse, Inside

    Description Part Function RFID reader To authorize the start or stop of a charging session with an RFID card Type plate To show the identification data of the EVSE. Refer to sec- tion 2.4.3 Overview of the EVSE, inside Maintenance cover Smart meter connection Ethernet connection Terminal block for the AC input...
  • Page 15: Options

    Description Options 2.5.1 Display Display 2.5.2 EV charge cable, type 2 2.5.3 Socket, type 2 Socket The socket for an EV charge cable type 2 is available with or without a shutter. BCM.V3Y00.0-EN | 001...
  • Page 16: Ev Charge Cable, Type 1

    The load management feature prevents that the system exceeds the grid capacity and prevents damage of the fuses. At times when the current demand is high, the Terra AC will pause the charge session. The charge session will start again when there is availability on the grid.
  • Page 17: Control Elements

    Description Control elements 2.6.1 LED indicators Error LED Internet connection LED Charging LED EVSE on/off LED Cable and car detection, and car authorization LED Table 1: Error LED Status of the LED Status of the EVSE Error No error Table 2: Charging LED Status of the LED Status of the EVSE EV is fully charged or has stopped charg-...
  • Page 18 Description Table 3: Cable and car detection, and car authorization LED Status of the LED Status of the EVSE A car is connected. The connection is au- torized. No car connected Flashing A car is connected, waiting for authoriza- tion Table 4: Internet connection LED Status of the LED Status of the EVSE...
  • Page 19: Safety

    Safety Safety Liability The manufacturer is not liable to the purchaser of the EVSE or to third parties for damages, losses, costs or expenses incurred by the purchaser or third parties if any target group mentioned in the related documents does not obey the rules below: 1.11 •...
  • Page 20: Personal Protective Equipment

    Safety Personal protective equipment Symbol Description Protective clothing Safety gloves Safety shoes Safety glasses General safety instructions • This document, the related documents and the warnings included do not replace your responsibility to use your common sense when you do work on the EVSE. •...
  • Page 21: Safety Instructions During Cleaning Or Maintenance

    Safety Safety instructions during cleaning or maintenance Preliminary requirements • • Keep unauthorized personnel at a safe distance during cleaning or maintenance. • If for cleaning or maintenance it is necessary to remove safety devices, immediately install the safety devices after the work. •...
  • Page 22: Discard Parts Or The Evse

    Safety Discard parts or the EVSE • Obey the local rules to discard parts, packaging material or the EVSE. BCM.V3Y00.0-EN | 001...
  • Page 23: Operation

    Operation Operation Prepare before use 1. Appoint a site operator and an installation engineer, if these are other persons than you. 2. Make sure that the equipment is installed and commissioned according to the instructions in the installation manual. 3. Make an emergency plan that instructs people what to do in case of an emergency. 4.
  • Page 24: Start A Charge Session

    Operation Start a charge session 4.4.1 EVSE with an EV charge cable Caution: During the charge session, do not disconnect the EV charge cable from the connection on the EV. There is a risk of damage of the connector of the EV.
  • Page 25: Evse With A Socket

    Operation 1. Select one of the two ways to end the charge session. • Wait until the charge session is completed. • The mobile app shows that the EV is fully charged. • The charging LED is on. • If your EVSE has a display, the display shows that the EV is fully charged. When the charge session is completed, the EVSE disconnects the power supply automatically.
  • Page 26: Wrap The Ev Charge Cable Around The Enclosure

    Operation Wrap the EV charge cable around the enclosure 1. Wrap the EV charge cable around the enclosure. BCM.V3Y00.0-EN | 001...
  • Page 27: Maintenance And Cleaning

    Maintenance and cleaning Maintenance and cleaning Maintenance schedule Task Frequency Procedure Clean the cabinet cover and 4 months Refer to section the enclosure of the EVSE. Do a visual check for dam- Before each use Refer to section age on the cabinet. Do a visual check for dam- Before each use Refer to section...
  • Page 28: Do A Check On The Cabinet

    Maintenance and cleaning Do a check on the cabinet 1. Do a check for damage on these parts: Part Damage Charge cables, outlets and connectors Cracks or ruptures Internal wires of the cable are visible Display Cracks Coating of the cabinet Cracks or ruptures 1.12 2.
  • Page 29: Troubleshooting

    Troubleshooting Troubleshooting Troubleshooting procedure 1. Try to find a solution for the problem with the aid of the information in this document. 2. If you cannot find a solution for the problem, contact your local representative of the 1.12 manufacturer. Refer to section Troubleshooting table Problem Possible cause...
  • Page 30 Troubleshooting Problem Possible cause Possible solution There is a relay con- The relay contact is over- 1. Examine the relay contact. tact failure heated or defective. 2. If necessary, contact your local representative of the manufac- turer or a qualified electrical contractor.
  • Page 31: De-Energize The Evse

    Troubleshooting Problem Possible cause Possible solution The car connection The EV charge cable is de- 1. Examine the EV charge cable. or authorization fective. 2. If the EV charge cable is defec- process fails tive, contact your local repre- sentative of the manufacturer or a qualified electrical contractor.
  • Page 32 Troubleshooting Error code Short description Description 0x0106 Residual current The residual current monitoring sensor is defec- monitor selftest error tive. 0x0108 Relay stuck error The relay contact is overheated or has damage. 0x0110 Cable undercapacity On the socket version of the EVSE, the rated current capacity of the cable is less than the rat- ed current of the EVSE.
  • Page 33: Technical Data

    Not certified SIM slot Display Example Terra AC W22-SR-0 • A1 = Brand name = Terra AC • A2 = Type = Wallbox • A3 = 22, Power output = 22 kW • A4 = Cable type, socket = type 2 socket with shutter...
  • Page 34: General Specifications

    Technical data • A5 = not applicable for socket version • A6 = authorization = RFID enabled • A7 = Ethernet = single • A8 = metering = not certified • A9 = SIM slot = applicable • A10 = display = not applicable •...
  • Page 35: Dimensions

    Technical data Dimensions 7.5.1 AC input with socket, cable Type 2 Width of the EVSE Height of the EVSE Depth of the EVSE Distance from the bottom of the Depth of the socket EVSE to the center of the socket. Parameter Value [mm] BCM.V3Y00.0-EN | 001...
  • Page 36: Ac Input With Ev Charge Cable

    Technical data 7.5.2 AC input with EV charge cable Width of the EVSE Height of the EVSE Depth of the EVSE Parameter Value [mm] 7.5.3 Space requirements for installation EVSE BCM.V3Y00.0-EN | 001...
  • Page 37: Ac Input Specifications

    Technical data Parameter Specification [mm] Specification [inches] > 200 > 8 Z2 (indoor use) > 457.2 > 18 Z2 (outdoor use) > 635 > 25 AC input specifications 7.6.1 General specifications Parameter Specification Earthing systems TN-S TN-C-S Frequency 50 Hz or 60 Hz Overvoltage category Category III Protection...
  • Page 38: Ac Output Specifications

    Technical data AC output specifications 7.7.1 AC output specifications (Europe) Parameter Specification AC output voltage range (1 phase) 220 - 240V AC AC output voltage range (3 phase) 380 - 415V AC Connection standard • Type 1 cable • Type 2 cable •...
  • Page 39 Technical data BCM.V3Y00.0-EN | 001...

Table of Contents