Connect The Ac Input Cable; Communication Connections; Insert The Ethernet Cable - ABB Terra AC Installation Manual

Hide thumbs Also See for Terra AC:
Table of Contents

Advertisement

Electrical installation
7.3

Connect the AC input cable

Preliminary requirements
Procedure
4. Connect the below wires:
1. Earthing (grounding) wire
2. L2 AC input wire (B)
3. L1 AC input wire (C)
5. Tighten the screws(D) to the
correct
torque. For the specification,
refer to section 10.14.
6. Install the protect cover(F).
7.4

Communication connections

7.4.1

Insert the Ethernet cable

Preliminary requirements
Procedure
1. Remove the grommet (A) from the
EVSE.
2. Install the conduit.
3. Put the Ethernet cable (B) through the
cable inlet hole.
34
Torque screwdriver
(A)
1.
The cabinet cover is removed.
2.
The maintenance cover is removed.
AC input cable (1 phase)

Advertisement

Table of Contents
loading