Lenovo ThinkSystem SD650-N Manual page 190

Neptune dwc tray and neptune dwc enclosure
Table of Contents

Advertisement

Severity: Warning
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: Address of the system where error occurred [arg3]: Page retire
PFA policy reached, "-T0";"-T1";"-T2";"-T3";"-T4". [arg4]: DIMM info (S/N, FRU and UDI.), e.g.
"739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Power off the system and remove the A/C power.
2. Reseat the affected DIMM.
3. Restore the A/C power and power on the system.
4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
5. Run advance memory test using the XClarity Provisioning Manager. Click Diagnostics > Run
Diagnostics > Memory Test > Advanced Memory Test to repair the DIMM.
6. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0058I: Memory mode is in flat mode, near memory/far memory ratio issue has recovered.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0058K: Near memory/far memory ratio (1:[arg1].[arg2]) for CPU high bandwidth memory
cache mode configuration is not in recommended range (1:[arg3] - 1:[arg4]).
Severity: Warning
Parameters:
[arg1]: The integer part of Far Memory(DDR5) ratio [arg2]: The decimal part of Far Memory(DDR5) ratio
[arg3]: Minimum range of Far Memory(DDR5) ratio [arg4]: Maximum range of Far Memory(DDR5) ratio
User Action:
Complete the following steps:
1. Validate system's memory configuration by using the memory configuration tool below: https://dcsc.
lenovo.com/#/memory_configuration.
2. Change the DIMM configuration so that the Near Memory/Far Memory ratio meets firmware
requirements, then reboot the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0059I: Bank sparing performed on CPU [arg1] high bandwidth memory channel [arg2]
pseudo-channel [arg3].
Severity: Info
Parameters:
[arg1]: CPU number, 1 - based (silk label #) [arg2]: Channel number, 0 – based number at socket level
[arg3]: Pseudo-channel number, 0 – based at channel level
User Action:
Information only; no action is required.