Lenovo ThinkSystem SD650-N Manual page 102

Neptune dwc tray and neptune dwc enclosure
Table of Contents

Advertisement

User Action:
Complete the following steps:
1. If the system board or firmware was just updated, check the Lenovo support site for an applicable
service bulletin or firmware update that applies to this processor error.
2. If problem persists, collect Service Data log.
3. Contact Lenovo Support.
• FQXSPPU0009N: [ProcessorElementName] has a Configuration Mismatch.
This message is for the use case when an implementation has detected a Processor Configuration
Mismatch has occurred.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0062
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
processor error.
2. If problem persists, collect Service Data log.
3. Contact Lenovo Support.
• FQXSPPU0010G: The Processor [ProcessorElementName] is operating in a Degraded State due to
[ProcessorElementName].
This message is for the use case when an implementation has detected a Processor is running in the
Degraded state.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - CPU
SNMP Trap ID: 42
CIM Prefix: PLAT CIM ID: 0038
User Action:
Complete the following steps:
1. Check the event log of system management module and XClarity Controller for any cooling related
issue.
2. Make sure CDU supply water temperature and flow rate per tray is within operating specifications.
3. Make sure waterloop assembly and maifold are installed correctly.
4. Make sure that the room temperature is within operating specifications.
5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
• FQXSPPU0011N: An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has
asserted.
This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
Severity: Error