Parameters:
[arg1]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Information only; no action is required.
• FQXSFMA0010K: Invalid memory configuration for Sparing Mode. Please correct memory
configuration. [arg1]
Severity: Error
Parameters:
[arg1]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Ensure that all the DIMMs are enabled and functional by booting to F1 Setup or in XCC web .If any
DIMMs are non-functional adddress that first.
2. Make sure that the DIMM connectors are correctly populated for sparing mode, according to the
service information for this product.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0011I: Memory population change detected. [arg1]
Severity: Info
Parameters:
[arg1]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected, then
ignore this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
• FQXSFMA0012I: The PFA of DIMM [arg1] has been deasserted.
Severity: Info
Parameters:
[arg1]: Dimm Silk Label, 1-based
User Action:
Information only; no action is required.
• FQXSFMA0014I: Memory spare copy initiated. [arg1]
Severity: Info
Parameters:
[arg1]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Information only; no action is required.
• FQXSFMA0015I: Memory spare copy has completed successfully. [arg1]
.
177