Lenovo ThinkSystem SD650-N Manual page 113

Neptune dwc tray and neptune dwc enclosure
Table of Contents

Advertisement

This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required
• FQXSPSD0005I: Hot Spare enabled for drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required
• FQXSPSD0005L: Array [ComputerSystemElementName] is in critical condition.
This message is for the use case when an implementation has detected that an Array is Critical.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0174
User Action:
Replace the hard disk drive that is indicated by XCC event log.
• FQXSPSD0006L: Array [ComputerSystemElementName] has failed.
This message is for the use case when an implementation has detected that an Array Failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0176
User Action:
Complete the following steps:
1. Replace any hard disk drive that is indicated by XCC event log.
2. Re-create the array.
3. Restore the data from a backup.
.
Chapter 2
XClarity Controller events
109

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem dw612s7d7n

Table of Contents