2. Look for any other RAID-related errors.
3. Replace the drive and recreate array.
• FQXSPUN0023N: Sensor [SensorElementName] has transitioned to non-recoverable.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0530
User Action:
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reboot the system.
3. If the error continues, collect Service Data logs. Contact Lenovo Support.
• FQXSPUN0026I: Device [LogicalDeviceElementName] has been added.
This message is for the use case when an implementation has detected a Device was inserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0536
User Action:
Information only; no action is required
• FQXSPUN0048I: The RAID controller in PCI slot [arg1] in optimal status.
This message is for the use case when an implementation has detected a Sensor transition to the normal
state.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0518
User Action:
Information only; no action is required
• FQXSPUN0056G: Sensor [SensorElementName] has asserted.
This message is for the use case when an implementation has detected a Sensor has asserted.
Severity: Warning
Serviceable: No
Automatically notify Support: No
.
Chapter 2