User Action:
Complete the following steps:
1. Run advance memory test in XClarity Provisioning Manager > Diagnostics, Run Diagnostics >
Advance Memory Test to repair the high bandwidth memory.
2. If the problem persists, collect Service Data logs, and contact Lenovo Support.
• FQXSFMA0068M: High bandwidth memory attempt post package repair (PPR) exceeded threshold
at CPU [arg1] high bandwidth memory channel [arg2] pseudo-channel [arg3].
Severity: Warning
Parameters:
[arg1]: Socket number, 1-based. [arg2]: channel on socket [arg3]: Pseudo channel
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Restore A/C power and power on the system.
3. Reset UEFI to factory default settings.
4. Update UEFI firmware to the latest version.
5. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0069G: Page retire PFA threshold limit exceeded on high bandwidth memory CPU[arg1]
at address [arg2]. [arg3]
Severity: Warning
Parameters:
[arg1]: Socket number, 1-based. [arg2]: Address where error occurred [arg3]: Page Retire Type
User Action:
Complete the following steps:
1. Run advance memory test in XClarity Provisioning Manager > Diagnostics, Run Diagnostics >
Advance Memory Test to repair the high bandwidth memory.
2. If the problem persists, collect Service Data logs, and contact Lenovo Support.
• FQXSFMA0070G: Post package repair failure and Bank sparing occurred during POST on CPU
[arg1] high bandwidth memory channel [arg2] pseudo-channel [arg3].
Severity: Warning
Parameters:
[arg1]: Socket number, 1-based. [arg2]: channel on socket [arg3]: Pseudo channel
User Action:
Complete the following steps:
1. Reboot System.
2. If the problem persists, check the Lenovo support site for an applicable service bulletin or firmware
update for the system that applies to this error.
3. If the problem persists, collect Service Data logs, and contact Lenovo Support.
• FQXSFMA0071M: Bank sparing failure occurred during POST on CPU [arg1] high bandwidth
memory channel [arg2] pseudo-channel [arg3].