Lenovo ThinkSystem SD650-N Manual page 160

Neptune dwc tray and neptune dwc enclosure
Table of Contents

Advertisement

Table 3. Events organized by severity (continued)
Message String
Event ID
FQXSFIO0008M
An intra-board UPI dynamic link width reduction has been detected
on the link between processor [arg1] port [arg2] and processor [arg3]
port [arg4].
FQXSFIO0009M
An inter-board UPI dynamic link width reduction has been detected
on the link between processor [arg1] port [arg2] and processor [arg3]
port [arg4].
FQXSFIO0013I
The device found at Bus [arg1] Device [arg2] Function [arg3] could not
be configured due to resource constraints. The Vendor ID for the
device is [arg4] and the Device ID is [arg5]. The physical slot number
is [arg6].
FQXSFIO0016M
IFM: Reset loop avoided - Multiple resets not allowed.
FQXSFIO0021J
PCIe Error Recovery has occurred in physical [arg1] number [arg2].
The [arg3] may not operate correctly.
FQXSFIO0022J
PCIe Link Width has degraded from [arg1] to [arg2] in physical [arg3]
number [arg4].
FQXSFIO0023J
PCIe Link Speed has degraded from [arg1] to [arg2] in physical [arg3]
number [arg4].
FQXSFIO0024I
An error has been detected by the IEH on processor [arg1]. The type
of IEH is [arg2]. The index of the IEH is [arg3]. The value of
IehErrorStatus register is [arg4]. Please check error logs for additional
downstream device error data.
FQXSFIO0025I
An error has been detected by the IIO on processor [arg1]. The index
of the IIO stack is [arg2]. The type of IIO Internal Error is [arg3]. Please
check error logs for additional downstream device error data.
FQXSFIO0036G
PCIe Correctable Error Threshold limit has been exceeded at
Segment 0x[arg1] Bus 0x[arg2] Device 0x[arg3] Function 0x[arg4]. The
Vendor ID for the device is 0x[arg5] and the Device ID is 0x[arg6]. The
physical [arg7] number is [arg8].
FQXSFIO0041J
PCIe Leaky Bucket Event : [arg1] occurred at Segment [arg2] Bus
[arg3] Device [arg4] Function [arg5]. The physical [arg6] number is
[arg7].
FQXSFMA0016M
Memory spare copy failed. [arg1]
FQXSFMA0026G
Multi-bit CE occurred on DIMM [arg1], need to restart the system for
DIMM Self-healing to attempt post package repair (PPR).
FQXSFMA0027G
Multi-bit CE occurred on DIMM [arg1] different rows.[arg2]
FQXSFMA0027M
DIMM [arg1] Self-healing, attempt post package repair (PPR) failed at
Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6].
[arg7]
FQXSFMA0028M
DIMM [arg1] Self-healing, attempt post package repair (PPR)
exceeded DIMM level threshold [arg2] at Rank [arg3] Sub Rank [arg4]
Bank [arg5] Row [arg6] on Device [arg7]. [arg8]
FQXSFMA0029G
DIMM [arg1] Self-healing, attempt post package repair (PPR) failed
with out of resource. [arg2]
FQXSFMA0047M
SPD CRC checking failed on DIMM [arg1]. [arg2]
156
ThinkSystem SD650-N V3 Neptune DWC Tray and DW612S Neptune DWC Enclosure Messages and Codes Reference
Severity
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning

Advertisement