Parameters:
[arg1]: disabled slot [arg2]: disabled but detected dimms e.g. "DIMM 3,4 disabled due to memory module
power failure. DIMM 3,4 detected and good."
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Check DIMM slots specified in the message. If DIMM installed but undetected, remove it and then
restore the A/C power and power on the system.
3. If all DIMMs detected or error persists after removing undetected DIMMs, reseat all the DIMMs in the
slots specified by the message and then restore the A/C power and power on the system.
4. If the problem persists or undetected DIMM needs to be replaced, collect Service Data logs and
contact Lenovo Support.
• FQXSFMA0065I: Multi-bit CE of DIMM [arg1] has been deasserted after performing post package
repair. DIMM identifier is [arg2].
Severity: Info
Parameters:
[arg1]: Dimm Silk Label. [arg2]: Dimm info. (S/N, FRU and UDI.)
User Action:
Information only; no action is required.
• FQXSFMA0065M: Memory address parity error occurred on CPU [arg1] high bandwidth memory
channel [arg2] pseudo-channel [arg3].
Severity: Error
Parameters:
[arg1]: Socket number, 1-based. [arg2]: channel on socket.[arg3]: Pseudo channel.
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Restore A/C power and power on the system.
3. Check Lenovo Support site for an applicable service bulletin.
4. If the problem persists, collect Service Data logs, and contact Lenovo Support to have failure part
replacement.
• FQXSFMA0066I: High bandwidth memory attempt post package repair (PPR) succeeded at CPU
[arg1] high bandwidth memory channel [arg2] pseudo-channel [arg3].
Severity: Info
Parameters:
[arg1]: Socket number, 1-based. [arg2]: channel on socket. [arg3]: Pseudo channel
User Action:
Information only; no action is required.
• FQXSFMA0066M: Memory address parity error occurred on CPU [arg1] channel [arg2] with DIMM
[arg3].
Severity: Error
188
ThinkSystem SD650-N V3 Neptune DWC Tray and DW612S Neptune DWC Enclosure Messages and Codes Reference