Lenovo ThinkSystem SD650-N Manual page 110

Neptune dwc tray and neptune dwc enclosure
Table of Contents

Advertisement

This message is for the use case when an implementation has detected a Sensor transition to less severe
from critical.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0523
User Action:
Information only; no action is required
• FQXSPPW2063I: Sensor [SensorElementName] has transitioned to a less severe state from critical.
This message is for the use case when an implementation has detected a Sensor transition to less severe
from critical.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0523
User Action:
Information only; no action is required
• FQXSPPW4001I: PCIe Power Brake for [arg1] has been [arg2].
This message is for the use case where PCIe Power Brake.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0243
User Action:
Check if system have fan fail error, Raidlink CEM fail occurring or Ambient temperature over 35C,
implement the "error" service action to recovery the system and reduce ambient temperature under 35C.
• FQXSPPW4002I: Total graphics power value has exceeded the pre-configured limit.
This message is for the use case where total graphics power value value has exceeded the pre-configured
limit.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: IMM CIM ID: 0328
User Action:
Information only; no action is required.