Table 3. Events organized by severity (continued)
Message String
Event ID
FQXSFPU0023G
Secure Boot Image Verification Failure Warning.
Processor has been disabled.
FQXSFPU0033G
FQXSFPU0062F
System uncorrected recoverable error happened in Processor [arg1]
Core [arg2] MC bank [arg3] with MC Status [arg4], MC Address [arg5],
and MC Misc [arg6].
FQXSFPU4033F
TPM Firmware recovery is in progress. Please DO NOT power off or
reset system.
FQXSFPU4035M
TPM Firmware recovery failed. TPM chip may be damaged.
FQXSFPU4040M
TPM selftest has failed.
FQXSFPU4043G
TPM Firmware update aborted. System is rebooting...
FQXSFPU4050G
Failed to update TPM Firmware.
FQXSFPU4051G
Undefined TPM_POLICY found
FQXSFPU4052G
TPM_POLICY is not locked
FQXSFPU4053G
System TPM_POLICY does not match the planar.
FQXSFPU4054G
TPM card logical binding has failed.
FQXSFPU4062M
CPU debugging is activated for DCI interface.
FQXSFPW0001L
CMOS has been cleared.
FQXSFSM0002N
Boot Permission denied by Management Module: System Halted.
FQXSFSM0003N
Timed Out waiting on boot permission from Management Module:
System Halted.
FQXSFSM0004M
An XCC communication failure has occurred.
FQXSFSR0001M
[arg1] GPT corruption detected, DiskGUID: [arg2]
FQXSFSR0003G
The number of boot attempts has been exceeded. No bootable
device found.
FQXSFTR0001L
An invalid date and time have been detected.
FQXSFDD0004M
DRIVER HEALTH PROTOCOL: Reports 'System Shutdown' Required
Controller.
FQXSFDD0012K
SATA Hard Drive Error: [arg1].
FQXSFIO0005M
An intra-board UPI failure has been detected on the link between
processor [arg1] port [arg2] and processor [arg3] port [arg4].
FQXSFIO0006M
An inter-board UPI failure has been detected on the link between
processor [arg1] port [arg2] and processor [arg3] port [arg4].
FQXSFIO0007M
An error has been detected by the IIO on Bus [arg1]. The value of
Global Fatal Error Status register is [arg2]. The value of Global Non-
Fatal Error Status register is [arg3]. Please check error logs for
additional downstream device error data.
FQXSFIO0010M
An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The physical [arg6] number is [arg7].
158
ThinkSystem SD650-N V3 Neptune DWC Tray and DW612S Neptune DWC Enclosure Messages and Codes Reference
Severity
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Error
Error
Error
Error
Error
Error