Lenovo ThinkSystem SD650-N Manual page 188

Neptune dwc tray and neptune dwc enclosure
Table of Contents

Advertisement

• FQXSFMA0053G: An uncorrected memory error has been recovered by mirror on DIMM [arg1] at
address [arg2].[arg3]
Severity: Warning
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: Address of the system where error ocurred [arg3]: DIMM identifier
consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Keep the system running until next planned maintenance window.
2. During planned maintenance, power off the system and remove A/C power.
3. Reseat the failing DIMM identified by LightPath and/or event log entry.
4. Restore A/C power and power on the system.
5. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this
memory error.
6. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0053I: DIMM [arg1] re-enabled due to memory module combination updating.
Severity: Info
Parameters:
[arg1]: DIMM Silk Label list. (eg1. 1 2. 1 & 2 & 3).
User Action:
Information only; no action is required.
• FQXSFMA0053M: DIMM [arg1] not defective but disabled due to unsupported memory module
combination on CPU [arg2].
Severity: Warning
Parameters:
[arg1]: DIMM Silk Label list. (eg1. 1 2. 1 & 2 & 3).
User Action:
Complete the following steps:
1. This event could follow an uncorrectable memory error or failed memory test. Check the log and
resolve that event first. DIMMs disabled by other errors or actions could cause this event.
2. Ensure that the DIMM are populated in the correct sequence, according to the service information for
this product.
3. If DIMMs are present and properly installed, check for any lit DIMM connector error LEDs, and if
found, reseat those DIMMs, then check logs for memory diagnostic codes.
4. Reset UEFI to default settings.
5. If problem persists, update UEFI firmware.
6. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0054G: Mirror failover operation was successful. DIMM [arg1] has failed over to the
mirrored DIMM [arg2].[arg3]
Severity: Warning
Parameters:
184
ThinkSystem SD650-N V3 Neptune DWC Tray and DW612S Neptune DWC Enclosure Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem dw612s7d7n

Table of Contents