Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU
0123456"
User Action:
Collect Service Data logs and contact Lenovo Support.
• FQXSFMA0029I: The PFA of DIMM [arg1] has been deasserted after applying PPR for this DIMM.
[arg2]
Severity: Info
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU
0123456"
User Action:
Information only; no action is required.
• FQXSFMA0047M: SPD CRC checking failed on DIMM [arg1]. [arg2]
Severity: Warning
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU
0123456"
User Action:
Complete the following steps:
1. Perform a virtual reseat or AC cycle the server.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFMA0048M: DIMM [arg1] disabled due to PMIC failure during POST, DIMM identifier is [arg2].
Severity: Warning
Parameters:
[arg1]: disabled dimm [arg2]: DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Reseat the DIMM in the slot specified by the event message.
3. Restore A/C power and power on the system.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0049M: DIMM [arg1] disabled due to memory module power failure. DIMM [arg2]
detected and good, DIMM [arg3] not detected.
Severity: Warning