• FQXSFIO0015I: IFM: System reset performed to reset adapters.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFIO0016M: IFM: Reset loop avoided - Multiple resets not allowed.
Severity: Warning
User Action:
Complete the following steps:
1. Update all firmware (including adapter firmware) to the latest levels.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0017M: IFM: Error communicating with the XCC - IFM may not be deployed correctly.
Severity: Error
User Action:
Complete the following steps:
1. Update all system firmware (including adapter firmware) to the latest levels.
Note: If the device is part of a cluster solution, verify that the latest level of code is supported for the
cluster solution before the update.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0018I: IFM: Configuration too large for compatibility mode.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFIO0019J: PCIe Resource Conflict.
Severity: Error
User Action:
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded,
reseat the adapter and any attached cables.
2. Move the adapter to a different system slot, if available.
3. Check Lenovo Support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error.
Note: It may be necessary to configure slot to Gen1 or to use special utility software so that adapter
firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings
-> Devices and I/O Ports ->PCIe Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
4. If the problem persists, collect Service Data logs.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFIO0020J: PCIe Isolation has occurred in PCIe slot [arg1]. The adapter may not operate