1. Check the log for a separate error related to an associated PCIe device or NVME disk and resolve
that error.
2. Check the Lenovo Support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure that the PCIe device or NVME disk is installed in the compatible
PCIe slot or bay and a compatible cable is used. If not, performance of this device might be
impacted.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0001I: DIMM [arg1] Disable has been recovered. [arg2]
Severity: Info
Parameters:
[arg1]: DIMM slot silklabel [arg2]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10
FRU 0123456"
User Action:
Information only; no action is required.
• FQXSFMA0001M: DIMM [arg1] has been disabled due to an error detected during POST. [arg2]
Severity: Error
Parameters:
[arg1]: DIMM slot silklabel [arg2]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10
FRU 0123456"
User Action:
Complete the following steps:
1. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event
denoting detected change in DIMM population that could be related to this problem.)
2. Boot to F1 setup and enable the DIMM (For AMD, do not need to enable DIMM in Setup). Reboot the
system.
3. Update UEFI firmware to the latest version.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFMA0002I: The uncorrectable memory error state has been cleared.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0002M: An uncorrectable memory error has been detected on DIMM [arg1] at address
[arg2]. [arg3]
Severity: Error
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: Address of the system where error ocurred [arg3]: DIMM identifier
consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
.
173