GOX-2402MC-PGE | GOX-3201MC-PGE | GOX-5103MC-PGE | GOX-8901MC-PGE | GOX-12401MC-PGE
Pulse Generator Items
PulseGeneratorEndPoint
PulseGeneratorEndPointMs
(ms)
PulseGeneratorPulse
Width (ms)
PulseGeneratorRepeat
Count
PulseGeneratorClear
Activation
PulseGeneratorClear
Source
Setting Range
1 ~ 1048575
464063
-
25
-
25
0 ~ 255
0
0: Off
1: Rising Edge
2: Falling Edge
0: Off
3: Level High
4 :Level Low
0: Low
1: High
3: Acquisition
Trigger Wait
4: Acquisition Active
5: Frame Trigger
Wait
6: Frame Active
7: Exposur eActive
0: Off
8: FVAL
14-17: User Output
0-3
18: Action1
19: Action2
21: Line5 Opt In1
26: Nand0 Out
27: Nand1 Out
User Manual (Ver. 1.5) - Setting List (Feature Properties)
Default
Set the start point of the Low interval as a clock count.
When the counter reaches this value, the output will be
0.
Set the start point of the Low interval in milliseconds.
When the counter reaches this value, the output will be
0. The setting range varies depending on the
ClockPreScaler value.
PulseGeneratorEndPoint = (1/(PulseGeneratorClock *
1000)) * PulseGeneratorEndPoint
Display the High interval width of the pulse in
milliseconds. The duration between the Start Point and
End Point is calculated. The setting range varies
depending on the ClockPreScaler value.
PulseGeneratorPulseWidth = (1/
(PulseGeneratorClock * 1000)) *
(PulseGeneratorEndPoint - PulseGeneratorStartPoint)
Set the repeat count for the counter. When this is set to
0, a free counter is enabled with no repeat limit.
Set the clear signal condition for the count clear input
of the pulse generator.
Select the count clear input signal source.
- 101 -
Description