Actual Exposure Time; Rct Mode - JAI GOX-2402M-PGE User Manual

Cmos digital progressive scan monochrome and color camera with gige interface
Hide thumbs Also See for GOX-2402M-PGE:
Table of Contents

Advertisement

GOX-2402MC-PGE | GOX-3201MC-PGE | GOX-5103MC-PGE | GOX-8901MC-PGE | GOX-12401MC-PGE

Actual Exposure Time

Related Setting Items:
The actual exposure time will consist of the image sensor's offset duration (refer to the table below)
added to the setting configured on the camera.
Example for GOX-3201M-PGE
When ExposureMode is set to Timed and the exposure time is set to 1 μs, the actual exposure
l
time will be as follows: 1 μs + 13.7 μs (offset duration of image sensor) = 14.7 μs
When ExposureMode is set to TriggerWidth, the exposure is slightly longer than the width of
l
the trigger signal. To achieve an exposure time of 14.7 μs and the exposure time offset is 13.7
μs, use "14.7 μs - 13.7 μs = 1 μs" as the high or low time for the trigger signal.
The offset time varies depending on the model.
Model Name
GOX-2402MC-PGE
GOX-2402MC-PGE-CS
GOX-3201MC-PGE
GOX-3201MC-PGE-CS
GOX-5103MC-PGE
GOX-5103MC-PGE-CS
GOX-8901MC-PGE
GOX-12401MC-PGE

RCT Mode

Related Setting Items:
In RCT mode, the image is not output from the camera until FrameStartTrigger is input, but internally
the imaging operation is continued and the automatic gain control (AGC) function, the automatic
shutter control (ASC) function and the automatic white balance (AWB) function can be continued.
You can use RCT mode when:
ExposureMode is set to Timed, and FrameStartTrigger is set to On.
l
Sequencer Function
l
AcquisitionControl
Image Sensor's Offset
13.73μs
14.26μs
AcquisitionControl
= Off