JAI GOX-2402M-PGE User Manual page 86

Cmos digital progressive scan monochrome and color camera with gige interface
Hide thumbs Also See for GOX-2402M-PGE:
Table of Contents

Advertisement

GOX-2402MC-PGE | GOX-3201MC-PGE | GOX-5103MC-PGE | GOX-8901MC-PGE | GOX-12401MC-PGE
Device Control Items
DeviceTLVersionMinor
DeviceTLVersionSubMinor
DeviceLinkSelector
DeviceLinkSpeed
DeviceLinkHeartbeatMode
DeviceLinkHeartbeatTimeout
DeviceStreamChannelCount
DeviceEventChannelCount
DeviceCharacterSet
DeviceReset
DeviceRegistersEndianness
DeviceTemperatureSelector
DeviceTemperature
Timestamp
TimestampReset
TimestampLatch
TimestampLatchValue
UserDefinedValueSelector
UserDefinedValue
Setting Range
Default
0 (Fixed)
-
1 (Fixed)
-
0 (Fixed)
0
125000000
-
Bps
1:On (Fixed)
-
500000 ~
3000000
120000000
-
1 (Fixed)
-
1 (Fixed)
1: UTF8
(Fixed)
-
-
1:big-endian
(Fixed)
0: Main board
-
(Fixed)
-55 ~ 125
0
0 ~ 64bit max
0
-
-
-
-
0 ~ 64bit max
0
0: Value1
1: Value2
2: Value3
0: Value1
3: Value4
4: Value5
-2147483648
0
~ 2147483647
User Manual (Ver. 1.5) - Setting List (Feature Properties)
Indicates the minor version number of the device's Transport
Layer.
Indicates the sub minor version number of the device's Transport
Layer.
Select Link.
Displays the negotiated transmission rate.
Display whether Heartbeat mode is enabled/disabled.
Configure the timeout value for Heartbeat (unit: μs). Step: 1000
Display the number of supported stream channels.
Display the number of supported message channels.
Display the character encoding.
Reset the device.(After the camera receives this command, it
returns an ACK response and executes the reset.)
Display the register's endianness.
Select the area of the camera's interior for which to display the
temperature sensor's reading.
Display the internal temperature (°C) of the device specified by
DeviceTemperatureSelector.
Display the timestamp value (ns). Resets to 0 when the signed
maximum 64-bit value is exceeded.
Forcibly sets the timestamp's count value to 0.
Sets the timestamp's count value to TimestampLatchValue.
Maximum value Signed 64-bit max value.
Five 32bit data can be set and saved.
Selects one of the 32bit data (Value1 to Value5) set in
UserDefinedValueSelector, and reads and sets the value in
UserDefinedValue.
- 86 -
Description

Advertisement

Table of Contents
loading

Table of Contents