Pulsegenerator - JAI GOX-2402M-PGE User Manual

Cmos digital progressive scan monochrome and color camera with gige interface
Hide thumbs Also See for GOX-2402M-PGE:
Table of Contents

Advertisement

GOX-2402MC-PGE | GOX-3201MC-PGE | GOX-5103MC-PGE | GOX-8901MC-PGE | GOX-12401MC-PGE

PulseGenerator

Configure pulse generator settings.
Related Topic:
Pulse Generator
Pulse Generator Items
ClockPreScaler
PulseGeneratorClock (MHz)
PulseGeneratorSelector
PulseGeneratorLength
PulseGeneratorLengthMs
(ms)
PulseGeneratorFrequency
(Hz)
PulseGeneratorStartPoint
PulseGeneratorStartPointMs
(ms)
Setting Range
1 ~ 4096
4
-
18.5625
0:PulseGenerator0
0:PulseGenerator0
1 ~ 1048575
618750
-
33.333333
-
30
0 ~ 1048575
0
-
0
User Manual (Ver. 1.5) - Setting List (Feature Properties)
Default
Set the division value for the prescaler (12 bit) using
PixelClock as the base clock.
Set the clock used for the pulse generator. This value
is calculated using the ClockPreScaler value as a
base.
PulseGeneratorClock = 74.25 / ClockPreScaler
Select the pulse generator.
Set the maximum count-up value as a clock count.
Set the maximum count-up value in milliseconds.
This value is calculated using the
PulseGeneratorLength value as a base. The setting
range varies depending on the ClockPreScaler value.
PulseGeneratorLength = (1/(PulseGeneratorClock *
1000)) * PulseGeneratorLength
Set the maximum count-up value as a frequency.
This value is calculated using the
PulseGeneratorLength value as a base.
PulseGeneratorFrequency = 1sec /
PulseGeneratorLengthMs
Set the start point of the High interval as a clock count.
When the counter reaches this value, the output will be
1.
Set the start point of the High interval in milliseconds.
When the counter reaches this value, the output will be
1. The setting range varies depending on the
ClockPreScaler value.
PulseGeneratorStartPointMs =
1/PulseGeneratorClock * PulseGeneratorStartPoint