JAI GOX-2402M-PGE User Manual page 98

Cmos digital progressive scan monochrome and color camera with gige interface
Hide thumbs Also See for GOX-2402M-PGE:
Table of Contents

Advertisement

GOX-2402MC-PGE | GOX-3201MC-PGE | GOX-5103MC-PGE | GOX-8901MC-PGE | GOX-12401MC-PGE
Digital IO Control
Items
0: False
LineInverter
1: True
0: False
(Low)
LineStatus
1: True (High)
LineMode
5: OptoCoupled
LineFormat
7: Internal Signal
bit0:Unused (Fixed to 0)
bit1: Line2 (Opt Out1)
bit2 - 3: Unused (Fixed
to 0 )
bit4: Line5 (Opt In1)
LineStatusAll
bit5 - 11:Unused (Fixed
to 0 )
bit12: Nand0 In1
bit13: Nand0 In2
bit14: Nand1 In1
bit15: Nand1 In2
Setting Range
Default
0: False
0: False
-
User Manual (Ver. 1.5) - Setting List (Feature Properties)
Enable/disable polarity inversion for the selected input signal or
output signal.
Note: Line5 Opt In1 is fixed to "0".
Display the status of the input signal or output signal (True: High,
False: Low).
Display the input/output status (whether it is input or output).
0: Input (LineSelector = Line5 Opt In1, Nand0 In1, Nand0 In2,
-
Nand1 In1, Nand1 In2)
1: Output (Line2 Opt Out1)
2: InternalConnection (TimestampReset)
Display the signal format.
Default
-
LineSelector = Line2 Opt Out1,Line5 Opt In1: OptoCoupled
LineSelector= TimestampReset: Internal Signal
Display the input/output signal status. The state is shown with 16
-
bits.
- 98 -