Trigger Control - JAI GOX-2402M-PGE User Manual

Cmos digital progressive scan monochrome and color camera with gige interface
Hide thumbs Also See for GOX-2402M-PGE:
Table of Contents

Advertisement

GOX-2402MC-PGE | GOX-3201MC-PGE | GOX-5103MC-PGE | GOX-8901MC-PGE | GOX-12401MC-PGE

Trigger Control

Related Setting Items:
The camera allows the following controls to be performed via external trigger signals.
TriggerSelector
AcquisitionStart
AcquisitionEnd
FrameStart
AcquisitionTransferStart
Notes:
The settings for exposure control and triggers are related to each other. Be sure to configure
l
the settings described in
You can delay when exposure actually starts after a trigger is received for a specific amount
l
of time by configuring TriggerDelay.
Select the trigger type with TriggerSelector and set the following items for each trigger.
TriggerMode
Switch enable or disable.
Select the source signal (PulseGenerator0, UserOutput0-3, Software, Line5 Opt In, Nand0
Out, Nand1 Out).
TriggerSource
TriggerActivation Sets the polarity of the trigger signal.
TriggerDelay
You can specify a delay after receiving the trigger signal until the trigger is enabled.
AcquisitionControl
Start image acquisition in response to the external trigger signal input.
Stop image acquisition in response to the external trigger signal input.
Start capturing a one-frame image in response to the external trigger signal input.
Select this to perform exposure control using external triggers.
Note: The FrameStart Trigger can only be used when the
setting is set to Timed or TriggerWidth.
Start output of acquired image data in response to external trigger signal input
(delayed readout).
Note: The number of frames that can be acquired on this camera is 4 frames
(in Monoxx or Bayerxx
Exposure
Note: Trigger can be executed by TriggerSoftware[TriggerSelector] command only
when Software is set.
Description
Pixel
Format).
Mode.