4.11 ENERGY METERING MEASUREMENT

The Energy Metering measurement is available in W for the AC and AC+DC
quantities. The energy meters start and totalize the various types of energy
(the eight energy meters - 4 meters of energy consumed and 4 meters of energy
generated - are started).
To measure the energy metering, proceed as follows:
1. Set the switch to
2. Press the
Metering mode appears. The display reads Counting Off.
3. Connect the black lead to the COM terminal and the red lead to
+
the
terminals.
4. Place the test probes or the alligator clips of the black lead on the
neutral (N), then those of the red lead on the L phase.
5. Clamp around only the corresponding conductor, respecting the
direction of current flow (see § 4.10).
6. To start the metering, press the
Counting On.
The metering sequence is as follows:
The status of each meter is:
- On <=> metering in operation
- Off <=> metering stopped (values of the meters 0)
- Stop <=> metering stopped (values of the meters preserved)
Clamp-On Meter Model 607- User Manual
.
(long press). Start-up screen 1 in the Energy
button. The display reads