4.7 RESISTANCE MEASUREMENT Ω
WARNING:
the circuit is off and all capacitors have been discharged.
1. Set the switch to
displayed.
2. Connect the black lead to the COM terminal and the red lead to
+
the
terminal.
3. Connect the test probes or the alligator clips to the circuit or component
to be measured.
The measured value is displayed on the screen.

4.8 CURRENT MEASUREMENT (A)

The jaws are opened by pressing the trigger on the body of the meter. The arrow
on the jaws of the clamp-on meter (see the following diagram) should point in the
presumed direction of current flow, from the generator to the load. Make sure that
the jaws have closed correctly after clamping around the conductor.
NOTE:
The measurement results are optimal when the conductor is
centered in the jaws (aligned with the centering marks).
The device selects AC or DC automatically according to which measured value is
larger. The AC or DC symbol displays blinking in auto detect mode.
30
Before making a resistance measurement, make sure that
and press the
Clamp-On Meter Model 607 - User Manual
Ω
button. The
symbol is