The unit supports the Ember+ protocol in both the
provider role and the consumer role. Both roles
can be active at the same time.
GPIOs are available via the Ember+ Provider of the
unit.
Text information (e.g., phone numbers) can be
exchanged via the Ember+ Consumer of the unit.
The parameters for communication via Ember+
are configured on the EMBER+ page.
ACTIVATE EMBER+ PROVIDER: Activates the
Ember+ provider of the unit.
LAN INTERFACE: Select the IP address of the unit
to which the Ember+ consumers of other devices
can connect.
PORT N (CONSUMER N): Up to 6 consumers can
connect to the unit simultaneously. Each
consumer must use an individual port. Unused
ports should be set to '0'. (Default: 9000, 9001,
9002, ...)
Ember+ (2)
ACTIVATE EMBER+ CONSUMER: Activates the
Ember+ consumer of the unit. The unit can
connect to two providers simultaneously.
LAN INTERFACE: Select the IP address of the unit
through which it connects to the Ember+
providers of other devices.
TCP/IP ADDRESS / PORT: Enter the IP address
and port of each provider to which the unit should
connect.