AES67 RX STREAM: Shows the status of the
configured RX AES67 streams.
LED = reception status:
(green): Audio data is being received.
(red): No audio data is being received.
PACKET LOSS: Shows the number of packet losses of
the stream since the beginning of the measurement.
PTP STATE: Shows the state of the PTP clock
synchronisation. The unit can only operate as a slave.
MASTER: Shows the IP address of the PTP master.
PATH DELAY: Shows the time delay of the connection
to the PTP master.
IP PACKET LOSS COUNTER: Shows the number of
packet losses of the receive streams of the codec
channel since the device was started or the alarm
counters were reset.
REMOTE GPIO RECEPTION: Shows whether the
transmission of GPIO states is activated.
CONNECTED EMBER+ CONSUMER: Lists all Ember+
consumers that are connected to the Ember+
provider of the unit.
CONNECTED PCS: Lists all PCs that are connected
to the unit.
System Monitor (5)
CONFIGURATION DIALOGUE OPEN AT: The system
settings cannot be opened on more than one PC at
the same time. This line shows on which PC the
configuration is open.