The device can be monitored via a network
management system. The parameters for that are
configured on the SNMP page.
▪
The information accessible via SNMP can only be
read.
The device responds to Get requests and sends
▪
traps.
Find the MIB for the device in the installation
▪
directory of the PC software.
SNMP VERSION: Select the SNMP version. SNMPv1
▪
and SNMPv2c are supported.
READ / TRAP COMMUNITY: Enter a string for the
▪
READ community and a string for the TRAP
community.
SNMP PORT: Enter the local UDP port for receiving
▪
SNMP requests and sending SNMP responses. The
remote port is derived from the received SNMP
requests. (Default: 161)
SNMP (2)
▪
NMS 1-4: The unit can send traps to up to four
Network Management Systems. Traps are sent
when the following parameters are set for an
NMS:
LAN: The IP address of the device used to send
▪
SNMP traps.
▪
IP ADDR: The destination IP address.
PORT: The destination UDP port. (Default: 162)
▪
▪
SYSTEM DESCRIPTION: A device description. This
string is part of the standard MIB.
▪
CONTACT: The person responsible for this device.
This string is part of the default MIB.
▪
SYSTEM LOCATION: Physical location of the
device. This string is part of the standard MIB.