ENCODER / DECODER AUDIO LEVEL: Indicates
whether the corresponding audio signal has fallen
below the set threshold for the set period. This
alarm must be activated in the settings.
DHD AUDIO MATRIX: Shows whether the unit was
able to establish a connection to the configured
DHD core.
EMBER+ CONSUMER: Shows whether the unit was
able to establish a connection to the configured
Ember+ provider.
DECODER SYNC: Indicates whether the decoder can
decode the incoming data stream.
DECODER IP PACKET LOSS: Shows whether the
number of packet losses exceeds the threshold for
BAD stream quality as configured under Alarm
Signalling.
System Monitor (3)
SYSTEM STATE: General information about the
system state is displayed here.
SYSTEM TEMPERATURE: Displays the temperature
measured in the enclosure. Above 57°C, the
OVERHEATED alarm is triggered. The temperature
should always be kept below 50°C. To do this, it is
necessary to leave at least one unit of free space
above the device in the rack so that the heat can
escape via the ventilation grille in the enclosure lid.
DSP LOAD: Shows the current load of the DSP in
percent.
DATA INTERFACE STATE: Shows the status of the
RS232 data interfaces.
ABS. DATA RATES: Shows the current data rates of
the RS232 interfaces in the transmitting direction (TX)
and receiving direction (RX).