AVT MAGIC AC1 Go Configuration Manual page 133

Table of Contents

Advertisement

Status changes of the unit can be recorded in an
internal log file.
The log file is configured on the GENERAL settings
page.
In order to be able to evaluate the log file, the
Logfile Viewer, which is part of the PC software,
can be used.
Open the Logfile Viewer via Menu > Logfile
Viewer.
The individual events are displayed line by line in
the table on the left.
DATE: The date on which the event was recorded.
The correct date is only displayed if the unit has a
connection to an NTP server.
TIME (LOCAL): The time at which the event was
recorded. The correct time is only displayed if the
unit has a connection to an NTP server. The time is
converted to the time zone of the PC by the PC
software.
Logfile Viewer (2)
DURATION [d] hh:mm:ss,msec: Duration for which
the event was active in hours : minutes : seconds ,
milliseconds. This information is only available if it is
relevant.
TYPE: A short information about the type of event.
SOURCE: Source of the event, e.g., Channel, LAN.
STATUS: Shows the new state of the component.
OK: An alarm is reset.
ERROR: An alarm has occurred.
SET / CLEARED: TTL status
LAN mode (speed / duplex)
DESCRIPTION: A short text describing the event in
more detail or providing additional information.
FILTER: The list of events can be filtered. Check
the boxes of the categories which should be
displayed.
SET FILTER: The new filter settings are not applied
to the table until the SET FILTER key has been
pressed.

Advertisement

Table of Contents
loading

Table of Contents