AH Mo t io n – H ar d war e M a nu a l
Temperature Measurement Modules
You can assign input registers to a temperature measurement module through HWCONFIG in ISPSoft. The input
registers should be within the range between D0 and D65535. Take AH08TC-5A for example. The original input
registers are D0~D15. You can change the input device range from D0~D15 to D60~D75.
 The default input device range: D0~D151
 The user-defined input device range: D60~D75
_3
Motion Control Modules
You can assign input registers and output registers to a motion control module through HWCONFIG in ISPSoft. The
input registers should be within the range between D0 and D65535, and the output registers should be within the
range between D0 and D65535. Take AH04HC-5A for example. The original input registers are D0~D27. You can
change the input device range from D0~D27 to D200~D227.
 The default input device range: D0~D27
 The user-defined input device range: D200~D227
3 - 1 4