Terminal
1.
Common input terminals.
2.
The functions of the terminals:
X0.2, X0.3,
X1.4, X1.5
1. Differential input terminals.
2. The functions of the terminals:
X0.8+, X0.8-,
X0.9+, X0.9-
1.
Differential input terminals.
2.
The functions of the terminals:
X0.10+, X0.10-,
X0.11+, X0.11-
1. Common input terminals.
2. The functions of the terminals:
X0.12,
X0.13,
X0.14,
X0.15,
X1.0,
X1.1,
X1.2,
X1.3
Y0.8,
1. Pulse output temrinals (open collector).
Y0.9,
2. The function of the terminals:
Description
function as trigger signals for high-speed
captures.
High-speed count:
The terminals are the RESET input
terminals for counter 2~counter 5.
X0.2 is for counter 2.
X0.3 is for counter 3.
X1.4 is for counter 4
X1.5 is for counter 5
High-speed capture: X0.2 and X0.3 can function
as trigger signals for high-speed captures.
Motion control: The terminals are for a manual
pulse generator.
High-speed count:
The terminals are for counter 0.
X0.8+ and X0.8- are the A-phase inputs for
counter 0. X0.9+ and X0.9- are the
B-phase inputs for counter 0.
High-speed capture: The terminals can function
as trigger signals for high-speed captures.
Interrupt inputs
High-speed count:
The terminals are for counter 1.
X0.10+ and X0.10- are the A-phase inputs
for counter 1. X0.11+ and X0.11- are the
B-phase inputs for counter 1.
High-speed capture: The terminals can function
as trigger signals for high-speed captures.
Interrupt inputs
High-speed count:
The terminals are for counter 2~counter 5.
X0.12 and X0.13 are for counter 2.
X0.14 and X0.15 are for counter 3.
X1.0 and X1.1 are for counter 4.
X1.2 and X1.3 are for counter 5.
High-speed capture: The terminals can function
as trigger signals for high-speed captures.
Interrupt inputs:
X0.12, X0.13, X0.14 and X0.15 can function as
interrupt inputs.
Ch a pt er 3 Pr o duc t S pec if ic a t io ns
Rated input
Response
characteristic
Current
100kHz(*1)
5mA
1MHz
+/-5mA
1MHz
+/-5mA
100 kHz(*1)
5mA
200 kHz
15 mA
Voltage
24V
3_
+/-5V
+/-5V
24 V
24 V
3 - 5