Delta AH Motion Series Hardware Manual page 176

Table of Contents

Advertisement

AH Mo t io n – H ar d war e M a nu a l
Terminal
X0.0+, X0.0-,
X0.1+, X0.1-,
X0.2+, X0.2-,
X0.3+, and X0.3-
X0.8+, X0.8-,
X0.9+, and X0.9-
_4
X0.10+, X0.10-,
X0.11+, X0.11-,
X0.12+, X0.12-,
X0.13+, X0.13,
X0.14+, X0.14-,
X0.15+, and
X0.15-
Y0.8, Y0.9, Y0.10,
and Y0.11
4 - 4 0
Description
1.
Differential input terminals.
2.
The functions of the terminals:
High-speed count:
 The terminals are the RESET input terminals
for counter 0~counter 5.
 X0.0+ and X0.0- are for counter 0. X0.1+ and
X0.1- are for counter 1. X0.2+ and X0.2- are
for counter 2 and counter 4. X0.3+ and X0.3-
are for counter 3 and counter 5.
High-speed capture: The terminals can function
as trigger signals for high-speed captures.
1.
Differential input terminals.
2.
The functions of the terminals:
Motion control: The terminals are for a manual
pulse generator.
High-speed count:
 The terminals are for counter 0.
 X0.8+ and X0.8- are the A-phase input
terminals for counter 0. X0.9+ and X0.9- are
the B-phase input terminals for counter 0.
High-speed capture: The terminals can function
as trigger signals for high-speed capture s.
Interrupt inputs
1.
They are differential input terminals.
2.
The functions of the terminals:
Motion control: supports DOG signal input for axis
1 to axis 6. The function is applicable for inserting
single axis one-speed/two-speed motion.
High-speed count:
 The terminals are for counter 1~counter 5.
 AB-phsae pulse input:
A-phase: X0.10+ and X0.10- are the input
terminals for counter 1. X0.12+ and X0.12-
are the input temrinals for counter 2 and
counter 4. X0.14+ and X0.14- are the input
terminals for counter 3 and counter 5.
B-phase: X0.11+ and X0.11- are the input
terminals for counter 1. X0.13+ and X0.13-
are the input terminals for counter 2 and
counter 4. X0.15+ and X0.15- are the input
terminals for counter 3 and counter 5.
High-speed capture: The terminals can function
as trigger signals for high-speed captures.
Interrupt inputs
1.
The high-speed pulse output temrinals are transistors
whose collectors are open collectors.
2.
The function of the terminals:
High-speed comparison: The terminals can
function as high-speed comparison output
temrinals.
Rated input
Response
characteristic
Current
Voltage
200 kHz
5 mA
5~24 V
200 kHz
5 mA
5~24 V
200 kHz
5 mA
5~24 V
200 kHz
15 mA
24 V

Advertisement

Table of Contents
loading

Table of Contents