Hoops Not Scoring - Bay-Tek CONNECT 4 HOOPS Service Manual

Hide thumbs Also See for CONNECT 4 HOOPS:
Table of Contents

Advertisement

All ball sensor boards have 4 emitters and 1 detector on opposite sides of the board.
These infrared sensors create a beam which the ball breaks to score a hoop.
Because these are interchangeable, the far left (#1) board can be swapped into a location with a faulty emitter.
The far right (#8) board can be swapped into a location with a faulty detector.
Emitters
# 1
# 2
Sensor Boards are plugged into the Aux Board
#1 to #1
#2 to #2
#3 to #3
#4 to #4
#5 to #5
#6 to #6
#7 to #7
#8 to #8
Diagnostic Menu
To Enter the Diagnostic Menu:
Enter Main Menu and scroll down to "Diagnostics:" turn to ON
Exit Menu
The ball gate motor will cycle open, and this screen will appear:
The top column will show hoops scored.

HOOPS NOT SCORING

Detector
# 3
# 8 # 7 # 6 # 5 # 4 # 3 # 2 # 1
# 4
# 5
AACE10028
AACB10000
Control Board
44
# 6
# 7
The same cable goes to every
sensor, so the cables can be
swapped between sensors to
identify an issue.
8 cables per game. (AACE10028)