Dipswitches must be set correctly on the I/O Aux Boards or game will not know which is
left or right player.
Turn off game by flipping the power switch on the power strip.
Set dipswitches as shown:
Left Side (Red Player)
Both switches 1 and 2 should be set to OFF
There are also a 8 dip bank of dipswitches on the I/O Aux Boards.
SWITCH
1
Does not dispense tickets and clears all
2
Does not dispense tickets
3
Saves tickets owed and unused credits
1/2 TICKET PAYOUT
Dispenses 1/2 the amount of tickets as
4
shown on screen. It will round up odd
DISABLES LOW TICKET INPUT
Disables the low ticket message on
5
screen. This option should be enabled
when using a card swipe system
6
7
8

DIPSWITCH SETTINGS

DESCRIPTION
SHOW GAME
accumulated credits
AMUSEMENT ONLY
NJ LOCKOUT
after a power loss
amounts of tickets
NOT USED
NOT USED
NOT USED
Right Side (Yellow Player)
Set switch 1 to ON , Set switch 2 to OFF
ON OFF
X
X
X
X
X