SERIAL PROTOCOL
8083XDS-AD Analog and SD-SDI XDS Encoder
Command:
^AI<sp>pn<sp>baud<sp>ws<sp>par<cr>
or
^AI<cr>
Default:
none
The parameter baud specifies the baud rate that will be used.
permitted values of parameter baud are shown in the table below.
Parameter
Baud rate
12
1200
1200
1200
24
2400
2400
2400
48
4800
4800
4800
96
9600
9600
9600
192
19200
19200
19200
384
38400
If the optional port name parameter is missing, then the current control port
will be assumed. If no parameters are specified, the 8083XDS-AD will
respond with a report of the communication parameters of all the comm
ports as shown below.
Port A: 1200 7 Odd
Port B: 9600 8 None
Port C: 1200 7 Odd
Port D: 4800 8 None
Examples:
^AI<sp>19200<cr>
^AI<sp>P1<sp>96<sp>8<sp>N Sets Port A to 9600,8,N
4.3.2

Reset Encoder

This command immediately clears the input and output data queues and
resets the 8083XDS-AD to the Transparent State in Field 1 and Field 2.
Article and XDS output queues are not reset by this command. They must
be explicitly reset by using the queue articles and queue XDS commands.
(See sections 4.5.4 and 4.6.3.)
simultaneously sending data, this command only affects the fields and data
types that have not been appropriated by other control ports.
Command:
^F^F<cr>
Default:
none
Revision 1.0.2
Set baud rate to 19200
Because other control ports may be
The