8083XDS-AD Analog and SD-SDI XDS Encoder
Switch
Name
1
Not Used
2
Port B
3
Keyer Disable GPI
4
Factory Reset
5
Not Used
6
Quick Boot
7
Not used
8
Not used
Page 5-4
5.3.2.1 Safety Guidelines and Precautions concerning
the Use of 3V Lithium Batteries
Please observe the following warnings strictly. If misused, the batteries
may explode or leak, causing injury or damage to the equipment.
The batteries must be inserted into the equipment with the correct
polarity (+ and -).
Do not attempt to revive used batteries by heating, charging or other
means.
Do not dispose of batteries in fire. Do not dismantle batteries.
Do not short circuit batteries.
Do not expose batteries to high temperatures, moisture or direct
sunlight.
Do not place batteries on a conductive surface (anti-static work mat,
packaging bag or form trays) as it can cause the battery to short.

5.3.2.2 Procedure for Replacing the Battery

When you replace the battery the menu settings of the unit will be lost. To
facilitate restoring the menu settings it is recommended that you go through
each menu item and write down the menu setting.
Remove the top cover of the unit.
Carefully lift out the old battery.
Insert the new battery with the + side facing up. Make sure it is firmly
inserted into the socket.
Replace the top cover of the unit and apply power.
Using the procedure outlined in section 5.3.2 reset the unit to its factory
default settings. Using the front panel menu, restore the unit's
configuration that you wrote down before removing the battery.
Using the procedure in section A.4 to set the system time and date.
5.3.3

DIP Switch Functions

The main circuit board contains an 8 position DIP switch (S1) that invokes
setup and diagnostic functions. Most users will have no need to alter the
factory switch settings. The functions of each switch are described below.
Normal
Function when Open
Open
Open
Normal Port B Function
Open
Master Mode
Open
Open
Closed
Display boot messages
Open
Open

Table 5-1: DIP Switch Functions

Revision 1.0.2
Function when Closed
Engineering Function Only
Temporary (Sticky) Mode
Reset to factory defaults on power up
Faster boot up