Adjusting The Output Level Of The Ltc Generators; Adjusting The Baud Rate Of The Serial Ports; Selecting Active Or Passive Vtr Communications On The Auxcom Port - evertz HD9010-SIE Instruction Manual

Hdtv source id encoder
Table of Contents

Advertisement

Regardless of the setting of this menu control the HD9010-SIE requires a stable
video input for normal operation.

3.8.3. Adjusting the Output Level of the LTC Generators

LTC LEVEL
Ltc Level =xx
AUX LTC LEVEL
Aux Ltc Level =xx

3.8.4. Adjusting the Baud Rate of the Serial Ports

COM 1 BAUD RATE
Com 1 baud =xx
AUXCOM BAUD RATE
Aux Com Baud =xx

3.8.5. Selecting Active or Passive VTR Communications on the AUXCOM Port

SERIAL MODE
Ser mode active
Ser mode passive
OPERATION
HD9010-SIE High Definition Source ID Encoder Manual
The LTC LEVEL menu item is used to adjust amplitude of the main LTC
output. Turn the shaft encoder to adjust. The recommended output
level setting is 35, which is approximately 1 volt peak to peak.
The AUX LTC LEVEL menu item is used to adjust amplitude of the
auxiliary LTC output.
recommended output level setting is 35, which is approximately 1 volt
peak to peak.
The COM 1 BAUD RATE menu item is used to set the baud rate of the
COM 1 serial port. Turn the shaft encoder to adjust. This serial port is
used to receive LVS data or for debugging purposes (selected by the.
COM1 MODE menu item) Contact the factory for further information
about using this port for debugging. Note that the setting of this menu
item does not affect the LVS baud rate (see section 4.2) or the firmware
upgrade baud rate (see section 5.2).
The AUXCOM BAUD RATE menu item is used to set the baud rate of
the AUX COM serial port. Turn the shaft encoder to adjust. Note that
the setting of this menu item does not affect the VTR communications
baud rate (see section 4.1) As this serial port is not used for any other
purpose at this time, the AUXCOM BAUD RATE menu setting has no
effect.
The SERIAL MODE menu item is used determine if the HD9010-SIE
will passively listen to VTR communications or actively poll the VTR for
time and status information when it is in VTR SID or VTR LVS mode.
See section 2.7 for information about connecting the VTR or other
device to the AUXCOM serial port. The baud rate is fixed at 38,400 for
VTR communications.
Select Ser mode active to have the HD9010-SIE poll the VTR.
Select Ser mode passive to have the HD9010-SIE listen to
communications between the VTR and a controller.
Revision 1.2
Turn the shaft encoder to adjust.
The