5.1.6. Serial Ports
Standard: RS-232
Number: 2 ports
Baud Rate:
COM1:
57600 baud (115,200 for Rev 2 hardware) for firmware upgrades
Programmable for data broadcast applications
AUX COM: Programmable
Connectors: 9 pin female "D"
Control:
COM1:
firmware upgrades, time code data broadcast
AUX COM: Programmable - future use
5.1.7. Physical
Dimensions: 19" W x 1.75" H x 18.75" D.
(483mm W x 45mm H x 477mm D)
Weight:
8 lbs. (3.5Kg)
5.1.8. Electrical
Power:
Auto ranging, 100
Safety:
ETL listed.
Complies with EU safety directive
EMI/RFI: Complies with FCC Part 15 Class A,
EU EMC Directive
5.2.
UPGRADING THE FIRMWARE
5.2.1. Overview
The firmware in the HD9010-SIE is contained on a FLASH EPROM. From time to time firmware updates
will be provided to add additional features to the unit.
There are two different versions of hardware that may be installed in the HD9010-SIE. The HARDWARE
VERSION menu item will tell you whether you have Rev 1 (7700PB3) or Rev 2 (7700PH4) hardware
installed. The baud rate for upgrading firmware is set differently for the different revisions of the hardware.
You will need the following equipment in order to update the Firmware
•
PC with available communications port.
therefore a 486 PC or better with a 16550 UART based communications port is recommended.
•
"Straight-thru" serial extension cable (DB9 female to DB9 male) or (DB25 female to DB9 male).
•
Terminal program that is capable of Xmodem file transfer protocol. (such as HyperTerminal)
•
New firmware supplied by Evertz.
TECHNICAL DESCRIPTION
HD9010-SIE High Definition Source ID Encoder Manual
240 VAC, 50/60 Hz 30 VA.
The communication speed is 57600 or 115200 baud,
Revision 1.2
Page 5-2