Installation
• Make a panel cut-out on the panel with the dimensions shown below.
Unit: mm
B
Model
A
HG2G-5T
• Use the attached mounting clips to tighten the screws evenly to mount panel: screws must be applied on total of
four places for HG2G-5T and on total two places for HG1G with the specified torque.
Mounting clips can be attached to the left and right sides of HG2G-5T. However, if they are attached in such way,
there is a risk of not satisfying product specifications such as waterproof performance, shock resistance, and
vibration resistance performance.
Panel
• Do not tighten with excessive force, otherwise the main unit may warp and cause wrinkle on the display, or
impair the waterproof characteristics.
• If the mounting clips are tightened obliquely to the panel, the main unit may fall off the panel.
• When installing the main unit into a panel cut-out, make sure that the gasket is not twisted. Especially when re-
installing, take special care because any twists in the gasket will impair the waterproof characteristics. Also, if
the gasket comes off the main unit, align the convex part of the gasket with the concave part of the front case,
and then insert the gasket fully into the gasket mounting groove without twisting it.
A
+2.0
121.0
153.0
0
+1.0
HG1G
92.0
118.0
0
Unit : N∙m
Mounting Clip
Model
HG2G-5T
HG1G
Mounting Clip
MICRO/I Hardware Manual
B
Panel Thickness
+2.0
0
1.0 to 5.0
+1.0
0
Specified Torque
0.2 to 0.3
0.3 to 0.35
4 HG2G-5T, HG1G