  • Page 1 B-2336(0) Hardware Manual MICRO/I HG2J-7U, HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F/-5T, HG1G/1P...
  • Page 2 • Be certain to read this manual carefully before performing installation, wiring, or maintenance work, or operating the MICRO/I HG2J-7U,HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F/-5T, HG1G/1P (Hereinafter referred to as "MICRO/I"). If the MICRO/I is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
  • Page 3 SAFETY PRECAUTIONS HG1P: • For the emergency stop switch and the enabling switch on this product, note the following points: - Connect the emergency stop switch to function as either a category 0 or category 1 stop in accordance with EN 60204-1. - Perform regular checks to confirm that the emergency stop switch and enabling switch work properly.
  • Page 4 September 2023: First Edition Caution • All rights in this manual belong to IDEC Corporation. It may not be reproduced, reprinted, sold, transferred or rented without our permission. • The contents of this manual are subject to change without notice.
  • Page 5 Read this manual to ensure the correct understanding of the entire functions of this product. IDEC Corporation makes the latest product manual PDFs available on our website at no additional cost. Please download the latest product manual PDFs from our website.
  • Page 6 Symbols Used in this Manual Symbols Used in this Manual This manual uses the following symbols to facilitate explanation. Symbols Information that requires special attention. Failure to operate the product in accordance with the …… information provided can lead to serious injury or damage. Information relating to requests or material to reference in the use of a function ……...
  • Page 7 Abbreviations, Generic Terms, and Terminology Used in this Manual Abbreviations, Generic Terms, and Terminology Used in this Manual Item Description HG2J-7U The name is short for MICRO/I HG2J-7UT22TF-B. HG5G-V The name is short for MICRO/I HG5G-VFXT22MF-B. HG4G-V The name is short for MICRO/I HG4G-VCXT22MF-B. HG4G The name is short for MICRO/I HG4G-CJT22*F-B.
  • Page 8: Table Of Contents

    Contents Contents SAFETY PRECAUTIONS .................Preface-1 Revision history ....................Preface-3 Caution......................Preface-3 Trademarks....................Preface-3 Preface ......................Preface-4 Symbols Used in this Manual .................Preface-5 Abbreviations, Generic Terms, and Terminology Used in this Manual ....Preface-6 Chapter 1 Main Unit Specifications HG2J-7U .......................1-1 Packing Content ..................... 1-1 Type Number....................1-1 Part Names....................
  • Page 9 Contents HG2G-5T, HG1G ....................1-60 Packing Content.................... 1-60 Type Number....................1-61 Part Names....................1-61 External Interfaces ..................1-63 Specifications....................1-65 Dimensions....................1-68 Installation ....................1-70 Wiring ......................1-72 USB Cable Lock Pin Attachment..............1-73 4.10 Maintenance and Inspection ................1-74 HG1P ......................... 1-79 Packing Content....................
  • Page 10: Preface

    Contents Preface MICRO/I Hardware Manual...
  • Page 11: Chapter 1 Main Unit Specifications

    Main Unit Specifications Chapter 1 HG2J-7U 1.1 Packing Content Before installing the HG2J-7U, make sure that the model you have received is what you actually ordered, and no parts are damaged to accidents during shipping. Product Name & Appearance Quantity Description HG2J-7U Main unit...
  • Page 12: Part Names

    1 HG2J-7U 1.3 Part Names (10) Name Description Green (lit): Normal Operation Green (flash): Operating system is booting. (Normal Operation) Orange (lit): Operating system is booting. (Boot mode) POWER LED Orange (flash): Preparing to boot the operating system, running in boot mode. Red (lit): Main unit is damaged.
  • Page 13: External Interfaces

    • The serial interface (COM) can be used as the RS232C and RS422/485 interfaces at same time. • Use the SELV (Safety Extra-Low Voltage) circuit to connect each interface. Serial Interface (COM) ● Use applicable cables for wiring and recommended ferrules (made by IDEC, Phoenix Contact or Weidmüller) as follows. Interface Specification RS232C, RS422/485...
  • Page 14 1 HG2J-7U Using RS422/485 interface HG2J-7U is not equipped with terminating resistor. Insert a terminating resistor of an appropriate value (about 100 to 120 Ohm, 1/2 W minimum) between terminal number 8 (RDA) and terminal number 9 (RDB), if necessary. Terminal Number 8 (RDA) Terminal Number 9 (RDB) For details about inserting and removing wires, refer to “1.8 Wiring”...
  • Page 15: Specifications

    1 HG2J-7U 1.5 Specifications ■ Applicable Standards UL61010-1, UL61010-2-201, UL121201 Safety Standards CSA C22.2 No.61010-1-12 (c-UL), CSA C22.2 No.61010-2-201 (c-UL), CSA C22.2 No.213 (c-UL) EMC Standards IEC/EN 61131-2 ■ Environmental Specifications Ambient Operating Temperature -20 to +60°C (no freezing) Ambient Operating Humidity 10 to 90% RH (no condensation) Ambient Storage Temperature -20 to +70°C (no freezing)
  • Page 16 1 HG2J-7U ■ Performance Specifications TFT color LCD (TN Type) LCD Type Display Colors 65,536 Colors Effective Display Area 154.08 (W) × 85.92 (H) mm Display Resolution 800 (W) × 480 (H) dots Dot pitch 0.1926 (W) x 0.179 (H) mm Display View angle Left/Right/Top: 80°, Bottom: 60°...
  • Page 17 1 HG2J-7U ■ EMC Specifications Class A: 10m 40dBµV/m quasi-peak (30M to 230MHz) 47dBµV/m quasi-peak (230M to 1GHz) Radiated Emission Class A: 3m 76dBµV/m (Peak), 56dBµV/m (AVG) (1G to 3GHz) 80dBµV/m (Peak), 60dBµV/m (AVG) (3G to 6GHz) Contact: ±6kV Electrostatic Discharge Air: ±8kV 10V/m (80M to 1000MHz) 3V/m (1.4G to 2.0GHz)
  • Page 18: Dimensions

    1 HG2J-7U 1.6 Dimensions Unit: mm 186.0 176.2 <Cable Attached Dimensions> 176.2 Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only. MICRO/I Hardware Manual...
  • Page 19: Installation

    1 HG2J-7U About the printed contents of the main unit ● "Mark A" indicates that you can refer to the instruction sheet using the QR code. For details, refer to “1.8 Wiring” on page 1-12. Mark A <QR code> See instr. Manual.
  • Page 20 1 HG2J-7U Installation ● • Make a panel cut-out on the panel with the dimensions shown below. Unit: mm Panel Thickness +1.0 +1.0 118.6 176.6 1.0 to 5.0 • Use the attached mounting clips to tighten the screws evenly to mount panel: screws must be applied on total of four places with the specified torque 0.5 to 0.6N∙m.
  • Page 21 1 HG2J-7U Restrictions due to mounting orientation ● The HG2J-7U is designed to install on a vertical landscape. The ambient operating temperature and the output current of the USB interface (total of USB1 and USB2) are limited depending on the mounting orientation as shown in the table below.
  • Page 22: Wiring

    • Pin assignment is shown in the following table. Power supply 12V/24V DC Power supply 0V (0V) Functional Earth (FE) • Use applicable cables for wiring and recommended ferrules (made by IDEC, Phoenix Contact or Weidmüller) as follows. Applicable cable AWG14 to 28...
  • Page 23 (3) Insert the power plug of the personal computer into the AC outlet. Recommended Tools ● Tool Name Model Number (Order Number) Manufacturer Normal type SDS 0.4×2.5×75 (9009030000) Weidmüller Flat blade screwdriver S3TL-D04-25-75 IDEC With insulated cover SDIS 0.4×2.5×75 (9008370000) Weidmüller S3TL-CR06D IDEC Crimping tool PZ6/5 (90011460000) Weidmüller S3TL-ST06 IDEC...
  • Page 24: Maintenance And Inspection

    The HG2J-7U’s backlight cannot be replaced by the customer. When the backlight needs to be Backlight replaced. Contact your vendor or IDEC Corporation. Maintenance Screen ● Turn on the power to the HG2J-7U, then press and hold the touch panel on the upper-left corner of the screen for three seconds or longer.
  • Page 25: Software License Information

    >> 1.10 Software License Information This product contains various open source software in addition to the software owned by IDEC Corporation. Information about open source software can be obtained from the QR code printed on the back of the HG2J-7U.
  • Page 26: Hg5G/4G/3G/2G-V

    2 HG5G/4G/3G/2G-V HG5G/4G/3G/2G-V 2.1 Packing Content Before installing the HG5G/4G/3G/2G-V, make sure that the model you have received is what you actually ordered, and no parts are damaged to accidents during shipping. ■ HG5G/4G/3G-V Product Name & Appearance Quantity Description HG5G/4G/3G-V Main unit Instruction Sheet...
  • Page 27: Type Number

    2 HG5G/4G/3G/2G-V 2.2 Type Number AUDIO IN/VIDEO IN Bezel Color Type Number 15.0 inch With Black HG5G-VFXT22MF-B 12.1 inch With Black HG4G-VCXT22MF-B Light gray HG3G-VAXT22MF-W 10.4 inch With Black HG3G-VAXT22MF-B Light gray HG3G-V8XT22MF-W 8.4 inch With Black HG3G-V8XT22MF-B Light gray HG2G-V5FT22TF-W 5.7 inch Without...
  • Page 28 2 HG5G/4G/3G/2G-V ■ HG3G-VA (10.4 inch) (12) (13) (14) (11) (10) (15) (4) (5) (6) (7) (16) (17) ■ HG3G-V8 (8.4 inch) (12) (13) (14) (11) (10) (15) (4) (5) (6) (7) (16) (17) ■ HG2G-V (5.7 inch) (11) (12) (13) (14) (15) (5) (6) (10) (9)
  • Page 29 (11) Memory Card Interface (SD) For SD memory card (12) SD Memory Card Access Lamp (13) Expansion Module Interface (EXT) For IDEC MICROSmart Expansion Modules (14) Battery Cover (15) Terminating Resistor Selector Switch For COM2 RS422/485 interface NTSC/PAL (16) Video Interface (VIDEO IN1)
  • Page 30: External Interfaces

    2 HG5G/4G/3G/2G-V 2.4 External Interfaces • Make sure to turn off the power to the HG5G/4G/3G/2G-V before wiring each interface or switching the terminating resistor selector switch. • The serial interface (COM 1) is used only for the interface of RS232C or RS422/485. Wiring both interfaces will result in failure of the HG5G/4G/3G/2G-V.
  • Page 31 Expansion Module Interface (EXT) ● IDEC MICROSmart expansion modules can be connected to the HG5G/4G/3G/2G-V. Refer to Chapter 2 “1.2 Applicable Expansion Modules” on page 2-2 for the number, the types and the combination of the expansion modules that can be installed.
  • Page 32: Specifications

    2 HG5G/4G/3G/2G-V 2.5 Specifications ■ Applicable Standards UL61010-1, UL61010-2-201, UL121201 Safety Standards CSA C22.2 No.61010-1-12 (c-UL), CSA C22.2 No.61010-2-201 (c-UL) CSA C22.2 No.213 (c-UL) EMC Standards IEC/EN 61131-2 Marine Standards LR, DNV·GL, ABS, ClassNK Environmental Specifications ■ Ambient Operating Temperature -20 to +60°C (no freezing) Ambient Operating Humidity 10 to 90% RH (no condensation)
  • Page 33 2 HG5G/4G/3G/2G-V ■ Performance Specifications Type Number HG5G-V HG4G-V HG3G-VA HG3G-V8 HG2G-V TFT color LCD TFT color LCD TFT color LCD (IPS Type) LCD Type (TN Type) (TN Type) Display Colors 65,536 Colors 245.76 (W) × 210.4 (W) × 170.496 (W) × 304.1 (W) ×...
  • Page 34 2 HG5G/4G/3G/2G-V ■ EMC Specifications Class A: 10m Radiated Emission 40dBµV/m quasi-peak (30M to 230MHz) 47dBµV/m quasi-peak (230M to 1GHz) Contact: ±6kV Electrostatic Discharge Air: ±8kV 10V/m (80M to 1000MHz) 3V/m (1.4G to 2.0GHz) Electromagnetic Field 1V/m (2.0G to 2.7GHz) 80% AM (1kHz) Power: ±2kV Fast Transient/Burst...
  • Page 35: Dimensions

    2 HG5G/4G/3G/2G-V 2.6 Dimensions ■ HG5G-V (15.0 inch) Unit: mm #33 48.8 364.5 69.5 54.8 351.5 # The size to the expansion module installation side <Cable Attached Dimensions> 351.5 Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only.
  • Page 36 2 HG5G/4G/3G/2G-V ■ HG4G-V (12.1 inch) Unit: mm #32.3 48.1 44.4 54.1 # The size to the expansion module installation side <Cable Attached Dimensions> Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only.
  • Page 37 2 HG5G/4G/3G/2G-V ■ HG3G-VA (10.4 inch) Unit: mm #30.9 46.7 44.4 52.7 257.5 # The size to the expansion module installation side <Cable Attached Dimensions> 257.5 Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only.
  • Page 38 2 HG5G/4G/3G/2G-V ■ HG3G-V8 (8.4 inch) Unit: mm #32.6 48.4 15.2 54.4 218.5 # The size to the expansion module installation side <Cable Attached Dimensions> 218.5 Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only.
  • Page 39 2 HG5G/4G/3G/2G-V ■ HG2G-V (5.7 inch) Unit: mm #33.6 167.2 49.4 54.4 152.5 # The size to the expansion module installation side <Cable Attached Dimensions> 152.5 49.4 Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only.
  • Page 40: Installation

    2 HG5G/4G/3G/2G-V 2.7 Installation Operating Environment ● For designed performance and safety of the HG5G/4G/3G/2G-V, do not install the HG5G/4G/3G/2G-V in the following environments: • Where dust, briny air, or iron powder exist. • Where oil or chemical splashes for a long time. •...
  • Page 41 2 HG5G/4G/3G/2G-V Installation ● • Make a panel cut-out on the panel with the dimensions shown below. Unit: mm Model Panel Thickness +2.0 +2.0 HG5G-V 279.0 352.0 2.0 to 5.0 +2.0 +2.0 HG4G-V 227.5 301.5 2.0 to 5.0 +2.0 +2.0 HG3G-VA 200.0 258.0...
  • Page 42 2 HG5G/4G/3G/2G-V Restrictions due to mounting orientation ● The HG5G/4G/3G/2G-V is designed to install on a vertical landscape. The ambient operating temperature and the use of expansion modules are limited depending on the mounting orientation as shown in the table below. Ambient Operating Temperature Orientation w/o expansion modules...
  • Page 43: Wiring

    2 HG5G/4G/3G/2G-V 2.8 Wiring • Turn off the power supply before wiring. • Make the wiring as short as possible and run all wires as far away as possible from high-voltage and large- current cables. Follow all the procedures and precautions when wiring the HG5G/4G/3G/2G-V. •...
  • Page 44: Usb Cable Lock Pin Attachment

    2 HG5G/4G/3G/2G-V 2.9 USB Cable Lock Pin Attachment When using the USB device, attach the USB Cable Lock Pin to prevent disconnecting the USB cable from the HG5G/4G/ 3G/2G-V. Insert the USB cable into the USB2 port. Strain the “Edge part” of the USB Cable Lock Pin, and insert the “Edge part” to the 2 holes upper the USB2 port. Clamp part Edge part HG5G/4G/3G-V...
  • Page 45: Maintenance And Inspection

    The HG5G/4G/3G/2G-V’s backlight cannot be replaced by the customer. When the backlight Backlight needs to be replaced. Contact your vendor or IDEC Corporation. The operating life of the internal battery is approximately five years. It is recommended to replace the Backup Battery battery every five years even before the reminder message for battery replacement is displayed.
  • Page 46 • The operating life of the internal battery is approximately five years. It is recommended to replace the battery every five years even before the reminder message for battery replacement is displayed. • IDEC provides replacement service for the battery (at customer’s expense). Contact your vendor or IDEC Corporation.
  • Page 47 2 HG5G/4G/3G/2G-V System Mode ● Press the System Mode at the top of the Maintenance Screen. The Top Page Screen appears. IDEC HG G SERIES SYSTEM MODE TOP PAGE Offline Main Menu MAC Address 00:03:7B:F0:12:A8 IP Address 192.168.0.1(DHCP) 2010/OCT/14/THU 14:56:44...
  • Page 48 Press the Main Menu on the Top Page in System Mode. The Main Menu Screen appears. IDEC HG G SERIES SYSTEM MODE TOP PAGE...
  • Page 49: Hg4G/3G, Hg2G-5F

    3 HG4G/3G, HG2G-5F HG4G/3G, HG2G-5F 3.1 Packing Content Before installing the HG4G/3G, HG2G-5F, make sure that the model you have received is what you actually ordered, and no parts are damaged to accidents during shipping. ■ HG4G/3G Product Name & Appearance Quantity Description HG4G/3G...
  • Page 50: Type Number

    3 HG4G/3G, HG2G-5F 3.2 Type Number AUDIO IN/VIDEO IN Bezel Color Type Number Without Dark gray HG4G-CJT22TF-B 12.1 inch With Dark gray HG4G-CJT22MF-B Light gray HG3G-AJT22TF-W Without Dark gray HG3G-AJT22TF-B 10.4 inch Light gray HG3G-AJT22MF-W With Dark gray HG3G-AJT22MF-B Light gray HG3G-8JT22TF-W Without Dark gray...
  • Page 51: Part Names

    3 HG4G/3G, HG2G-5F 3.3 Part Names ■ HG4G (12.1 inch) (12) (13) (14) (11) (10) (15) (4) (5) (6) (7)(16)(17) ■ HG3G-A (10.4 inch) (12) (13) (14) (11) (10) (15) (4) (5) (6)(7)(16) (17) ■ HG3G-8 (8.4 inch) (12) (13) (14) (11) (10) (15)
  • Page 52 (11) Memory Card Interface (SD) For SD memory card (12) SD Memory Card Access Lamp (13) Expansion Module Interface (EXT) For IDEC MICROSmart Expansion Modules (14) Battery Cover (15) Terminating Resistor Selector Switch For COM2 RS422/485 interface LINE IN terminal (Stereo) Input impedance : 60kΩ...
  • Page 53: External Interfaces

    3 HG4G/3G, HG2G-5F 3.4 External Interfaces • Make sure to turn off the power to the HG4G/3G, HG2G-5F before wiring each interface or switching the terminating resistor selector switch. • Note that only one of the RS232C or RS422/485 interfaces can be used at same time. Wiring both interfaces will result in failure of the HG4G/3G, HG2G-5F.
  • Page 54 Expansion Module Interface (EXT) ● IDEC MICROSmart expansion modules can be connected to the HG4G/3G, HG2G-5F. Refer to Chapter 2 “1.2 Applicable Expansion Modules” on page 2-2 for the number, the types and the combination of the expansion modules that can be installed.
  • Page 55: Specifications

    3 HG4G/3G, HG2G-5F 3.5 Specifications ■ Applicable Standards UL508, ANSI/ISA-12.12.01 Safety Standard CSA C22.2 No.142 (c-UL), CSA C22.2 No.213 (c-UL) IEC/EN 61131-2 EMC Standard ABS, DNV, LR, NK Ship Classification Standard ■ Environmental Specifications Ambient Operating Temperature 0 to +50°C (no freezing) Ambient Operating Humidity 10 to 90% RH (no condensation) Ambient Storage Temperature...
  • Page 56 3 HG4G/3G, HG2G-5F ■ Performance Specifications Type Number HG4G HG3G-A HG3G-8 HG2G-5F TFT color LCD (TN Type) LCD Type Display Colors 65,536 Colors 246.0 (W) × 211.2 (W) × 170.4 (W) × 115.2 (W) × Effective Display Area 184.5 (H) mm 158.4 (H) mm 127.8 (H) mm 86.4 (H) mm...
  • Page 57: Dimensions

    3 HG4G/3G, HG2G-5F 3.6 Dimensions ■ HG4G (12.1 inch) Unit: mm #32.3 44.4 48.1 54.1 # The size to the expansion module installation side <Cable Attached Dimensions> Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only.
  • Page 58 3 HG4G/3G, HG2G-5F ■ HG3G-A (10.4 inch) Unit: mm #30.9 44.4 46.7 52.7 257.5 # The size to the expansion module installation side <Cable Attached Dimensions> 257.5 Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only.
  • Page 59 3 HG4G/3G, HG2G-5F ■ HG3G-8 (8.4 inch) Unit: mm #32.6 15.2 48.4 54.4 218.5 # The size to the expansion module installation side <Cable Attached Dimensions> 218.5 Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only.
  • Page 60 3 HG4G/3G, HG2G-5F ■ HG2G-5F (5.7 inch) Unit: mm 167.2 #33.6 152.5 # The size to the expansion module installation side <Cable Attached Dimensions> 49.4 152.5 Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only.
  • Page 61: Installation

    3 HG4G/3G, HG2G-5F 3.7 Installation Operating Environment ● For designed performance and safety of the HG4G/3G, HG2G-5F, do not install the HG4G/3G, HG2G-5F in the following environments: • Where dust, briny air, or iron powder exist. • Where oil or chemical splashes for a long time. •...
  • Page 62 3 HG4G/3G, HG2G-5F • Use the attached mounting clips to tighten the screws evenly to mount panel: screws must be applied on total of four places on top and bottom with the specified torque. If mounting clips are attached in the part besides the following figure, there is a risk of not satisfying product specifications such as waterproof performance, shock resistance, and vibration resistance performance.
  • Page 63 3 HG4G/3G, HG2G-5F Restrictions due to mounting orientation ● The HG4G/3G, HG2G-5F is designed to install on a vertical landscape. The ambient operating temperature and the use of expansion modules are limited depending on the mounting orientation as shown in the table below. Ambient Operating Temperature Orientation w/o expansion modules...
  • Page 64: Wiring

    3 HG4G/3G, HG2G-5F 3.8 Wiring • Turn off the power supply before wiring. • Make the wiring as short as possible and run all wires as far away as possible from high-voltage and large- current cables. Follow all the procedures and precautions when wiring the HG4G/3G, HG2G-5F. •...
  • Page 65: Usb Cable Lock Pin Attachment

    3 HG4G/3G, HG2G-5F 3.9 USB Cable Lock Pin Attachment When using the USB device, attach the USB Cable Lock Pin to prevent disconnecting the USB cable from the HG4G/3G, HG2G-5F. Insert the USB cable into the USB2 port. Strain the “Edge part” of the USB Cable Lock Pin, and insert the “Edge part” to the 2 holes upper the USB2 port. Clamp part Edge part HG4G/3G...
  • Page 66: Maintenance And Inspection

    The HG4G/3G, HG2G-5F’s backlight cannot be replaced by the customer. When the backlight Backlight needs to be replaced. Contact your vendor or IDEC Corporation. The operating life of the internal battery is approximately five years. It is recommended to replace the Backup Battery battery every five years even before the reminder message for battery replacement is displayed.
  • Page 67 • The operating life of the internal battery is approximately five years. It is recommended to replace the battery every five years even before the reminder message for battery replacement is displayed. • IDEC provides replacement service for the battery (at customer’s expense). Contact your vendor or IDEC Corporation.
  • Page 68 3 HG4G/3G, HG2G-5F System Mode ● Press the System Mode at the top of the Maintenance Screen. The Top Page Screen appears. IDEC HG G SERIES SYSTEM MODE TOP PAGE Offline Main Menu MAC Address 00:03:7B:F0:12:A8 IP Address 192.168.0.1(DHCP) 2010/OCT/14/THU 14:56:44...
  • Page 69 Press the Main Menu on the Top Page in System Mode. The Main Menu Screen appears. IDEC HG G SERIES SYSTEM MODE TOP PAGE...
  • Page 70 4 HG2G-5T, HG1G HG2G-5T, HG1G 4.1 Packing Content Before installing the HG2G-5T, HG1G, make sure that the model you have received is what you actually ordered, and no parts are damaged to accidents during shipping. ■ HG2G-5T Product Name & Appearance Quantity Description HG2G-5T...
  • Page 71 4 HG2G-5T, HG1G 4.2 Type Number Bezel Color Type Number Light gray HG2G-5TN22TF-W 5.7 inch TFT Monochrome Dark gray HG2G-5TN22TF-B Silver HG2G-5TN22TF-S Light gray HG2G-5TT22TF-W 5.7 inch TFT Color Dark gray HG2G-5TT22TF-B Silver HG2G-5TT22TF-S Black HG1G-4VT22TF-B 4.3 inch TFT Color Silver HG1G-4VT22TF-S 4.3 Part Names...
  • Page 72 4 HG2G-5T, HG1G ■ HG1G (1) (2) (8)(9) Name Description Display TFT color LCD Touch Panel Analog resistive membrane type Power Supply Terminal Connector: Terminal Block 3-pin (Screw fastened type) RS232C, RS422/485 Serial Interface (COM) Connector: Terminal Block 9-pin (Screw fastened type) Maximum cable length: 15m (RS232C), 1200m (RS422/RS485) IEEE802.3u 10BASE-T/100BASE-TX Ethernet Interface (LAN)
  • Page 73 4 HG2G-5T, HG1G 4.4 External Interfaces • Make sure to turn off the power to the HG2G-5T, HG1G before wiring each interface or switching the terminating resistor selector switch. • The serial interface can be used as the RS232C and RS422/485 interfaces at same time. Serial Interface ●...
  • Page 74 4 HG2G-5T, HG1G Using RS422/485 interface • For HG2G-5T, if you set the Terminating Resistor Selector Switch to the ON side, this will connect the internal terminating resistor (100Ω) between RDA and RDB. OFF  ON  Terminating Resistor Selector Switch (for RS422/485 interface) • HG1G is not equipped with terminating resistor. Insert a terminating resistor of an appropriate value (about 100 to 120 Ohm, 1/2 W minimum) between terminal number 8 (RDA) and terminal number 9 (RDB), if necessary.
  • Page 75 4 HG2G-5T, HG1G 4.5 Specifications ■ Applicable Standards UL508, ANSI/ISA 12.12.01, Safety Standard CSA C22.2 No.142 (c-UL), CSA C22.2 No.213 (c-UL) IEC/EN 61131-2 EMC Standard ■ Environmental Specifications Type Number HG2G-5T HG1G Ambient Operating Temperature -20 to +60°C (no freezing) -20 to +55°C (no freezing) Ambient Operating Humidity...
  • Page 76 4 HG2G-5T, HG1G ■ Performance Specifications Type Number HG2G-5TN HG2G-5TT HG1G TFT Monochrome LCD TFT Color LCD (TN Type) LCD Type (TN Type) Display Colors 2 Colors (16 tones) 65,536 Colors Effective Display Area 115.2 (W) × 86.4 (H) mm 95.04 (W) ×...
  • Page 77 4 HG2G-5T, HG1G ■ EMC Specifications Class A: 10m Radiated Emission 40dBµV/m quasi-peak (30M to 230MHz) 47dBµV/m quasi-peak (230M to 1GHz) Contact: ±6kV Electrostatic Discharge Air: ±8kV 10V/m (80M to 1000MHz) 3V/m (1.4G to 2.0GHz) Electromagnetic Field 1V/m (2.0G to 2.7GHz) 80% AM (1kHz) Power: ±2kV Fast Transient/Burst...
  • Page 78 4 HG2G-5T, HG1G 4.6 Dimensions ■ HG2G-5T (5.7 inch) Unit: mm 167.2 152.5 <Cable Attached Dimensions> 152.5 Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only. 1-68 MICRO/I Hardware Manual...
  • Page 79 4 HG2G-5T, HG1G ■ HG1G (4.3 inch) Unit: mm <Cable Attached Dimensions> Depending on the type of connection cable used the dimensions shown above will change. The dimensions given here are representative values and are intended for reference only. 1-69 MICRO/I Hardware Manual...
  • Page 80 4 HG2G-5T, HG1G 4.7 Installation Operating Environment ● For designed performance and safety of the HG2G-5T, HG1G, do not install the HG2G-5T, HG1G in the following environments: • Where dust, briny air, or iron powder exist. • Where oil or chemical splashes for a long time. •...
  • Page 81 4 HG2G-5T, HG1G Installation ● • Make a panel cut-out on the panel with the dimensions shown below. Unit: mm Model Panel Thickness +2.0 +2.0 HG2G-5T 121.0 153.0 1.0 to 5.0 +1.0 +1.0 HG1G 92.0 118.0 • Use the attached mounting clips to tighten the screws evenly to mount panel: screws must be applied on total of four places for HG2G-5T and on total two places for HG1G with the specified torque.
  • Page 82 4 HG2G-5T, HG1G 4.8 Wiring • Turn off the power supply before wiring. • Make the wiring as short as possible and run all wires as far away as possible from high-voltage and large- current cables. Follow all the procedures and precautions when wiring the HG2G-5T, HG1G. •...
  • Page 83 4 HG2G-5T, HG1G 4.9 USB Cable Lock Pin Attachment When using the USB device, attach the USB Cable Lock Pin to prevent disconnecting the USB cable from the HG2G-5T HG1G. Insert the USB cable into the USB2 port. Strain the “Edge part” of the USB Cable Lock Pin, and insert the “Edge part” to the 2 holes lower the USB2 port. Clamp part Edge part HG2G-5T...
  • Page 84 The HG2G-5T, HG1G’s backlight cannot be replaced by the customer. When the backlight needs Backlight to be replaced. Contact your vendor or IDEC Corporation. The operating life of the internal battery is approximately five years. It is recommended to Backup Battery replace the battery every five years even before the reminder message for battery replacement is displayed.
  • Page 85 • IDEC provides replacement service for the battery (at customer’s expense). Contact your vendor or IDEC Corporation. The battery may be regulated by national or local regulation. Observe the instructions of proper regulation. As...
  • Page 86 4 HG2G-5T, HG1G Handling of Batteries and Devices with Built-in Batteries in EU Member States Note: The following symbol mark is for EU countries only and is according to the directive 2006/66/EC Article 20 information for end-users and Annex II. This symbol mark means that batteries and accumulators, at their end-of life, should be disposed of separately from your household waste.
  • Page 87 4 HG2G-5T, HG1G Adjusting the Brightness ● The brightness of the HG2G-5T, HG1G display can be adjusted on the Adjust Brightness Screen. Press the Adjust Brightness at the bottom of the Maintenance Screen. The Adjust Brightness Screen appears. Maintenance System Mode Device Monitor Adjust Brightness Press the <<...
  • Page 88 4 HG2G-5T, HG1G Adjusting the Touch Panel ● A gap may be caused in the operation accuracy of the touch panel by the secular distortion, etc. Adjust the touch panel according to the following procedure when there is a gap in the operation of the touch panel. Press the Main Menu on the Top Page in System Mode.
  • Page 89 5 HG1P HG1P 5.1 Packing Content Before installing the HG1P, make sure that the model you have received is what you actually ordered, and no parts are damaged to accidents during shipping. Product Name & Appearance Quantity Description HG1P Main unit Instruction Sheet Japanese, English Instruction Sheet...
  • Page 90 ⑫ ⑬ ⑭ ⑮ Name Description 1 (external wiring) Mechanical Switch 1 Type No.: AB6E-3BV02PRM (IDEC) (Emergency Stop Switch) Contact Rating: 1A/DC30V 1 (external wiring) Mechanical Switch 2 Type No.: LB6S-2T1 (IDEC) (Selector Switch) Contact Rating: 0.1A/DC30V (resistance load) Function Key...
  • Page 91 5 HG1P 5.4 External Interfaces • Make sure to turn off the power to the HG1P before inserting or pulling the cable into or out of the connector. • Communication interface specifications vary based on the model number. HG1P-ST32YBFH-B0: Serial Interface (RS422/485) Communication Interface Specifications HG1P-ST32ZBFH-B0: Ethernet Interface Connector...
  • Page 92 5 HG1P 5.5 Specifications The following specifications are when the HG1P optional cable, specified by IDEC, is attached. ■ Applicable Standards UL61010-, UL61010-2-201 Safety Standards CSA C22.2 No.61010-1 (c-UL), CSA C22.2 No.61010-2-201 (c-UL) IEC/EN 61131-2 EMC Standards Environmental Specifications ■...
  • Page 93 5 HG1P ■ Performance Specifications TFT color LCD LCD Type Display Colors 65,536 Colors Effective Display 95.04 (W) × 53.856 (H) mm Area Display Resolution 480 (W) × 272 (H) dots View angle Left/Right: 80°, Top: 65°, Bottom: 55° Display Brightness of LCD 400 cd/m only...
  • Page 94 5 HG1P ■ EMC Specifications Class A: 10m •IEC 61000-6-4 Class A 40dBμV/m quasi-peak (30M to 230MHz) 47dBμV/m quasi-peak (230M to 1GHz) Radiated Emission •FCC Class A 39dBμV/m quasi-peak (30M to 88MHz) 43.5dBμV/m quasi-peak (88M to 216MHz) 46.4dBμV/m quasi-peak (216M to 960MHz) 49.5dBμV/m quasi-peak (960M to 1GHz) Contact: ±4kV Electrostatic Discharge...
  • Page 95 5 HG1P ■ Switch Specifications Function Keys Model Tactile Switch Number Equipped Contact Normally open contact Device Name HMI Expansion Input (Bit) Internal Devices Symbol R/W is an abbreviation of Read/Write. R/W indicate that both reading and writing are possible, while R indicates that only reading is possible.
  • Page 96 • Be careful with the switch. If the switch is subjected to excessive shocks or vibrations, it may deform or become damaged, chattering may occur, operation may fail, or performance may become degraded. Part Number (Manufacturer) AB6E-3BV02PRM (IDEC) Number Mounted Contact...
  • Page 97 When wiring the contacts to two inputs so that they are monitored mutually, design the sequence control to take into consideration this time difference. Part Number (Manufacturer) HE6B-M200Y (IDEC) Number Mounted Contact 2 contacts (external wiring)
  • Page 98 5 HG1P Selector Switch (φ16 or Non-Illuminated model) Use the selector switch through the HG1P optional cable as a control signal for external devices. Part Number (Manufacturer) LB6S-2T1 (IDEC) Number Mounted Contact SPDT (external wiring) Contact Rating 0.1A/DC30V (resistance load)
  • Page 99 5 HG1P 5.6 Dimensions Unit: mm <Cable Dimensions> 1-89 MICRO/I Hardware Manual...
  • Page 100 5 HG1P 5.7 Installation Operating Environment ● • For designed performance and safety of the HG1P, do not install the HG1P in the following environments: - Where dust, briny air, or iron powder exist. - Where oil or chemical splashes for a long time. - Where space is filled with oil mist.
  • Page 101 5 HG1P Turn the shaded portion of the connector clockwise 90°. Before locking the connector After locking the connector The connector will stop turning at 90°. Do not try to turn it past 90°. Removing and Installing the USB Port Cover •...
  • Page 102 5 HG1P Installing the Hand Strap (HG9Z-PS4) Pass the hand strap through the hand strap mounting part. Hand Strap Hole Hand Strap Pass the end of the strap through the loop, keep holding the end, and pull it tight. The Loop of the Strap The End of the Strap Be careful when pulling the strap tight because the strap may be damaged if excessive force is used.
  • Page 103 5 HG1P 5.8 Wiring • Turn off the power supply before wiring. • Make the wiring as short as possible and run all wires as far away as possible from high-voltage and large- current cables. Follow all the procedures and precautions when wiring the HG1P. •...
  • Page 104 5 HG1P HG1P Debug Cable (HG9Z-PX12) ● This cable is the debug cable. Use this cable only for debugging. ■ Cable Specification Structure Double shield cable AWG25 x 2 Pair Configuration AWG23 x 5 Cores Conductor Configuration 40N/0.08mm(Pair), 60N/0.08mm(Cores) Material Insulator Thickness 0.16mm(Pair), 0.145mm(Cores)
  • Page 105 5 HG1P 5.9 Maintenance and Inspection Maintain and inspect the HG1P periodically to ensure the best performance. Do not disassemble, repair, or modify the HG1P during inspection. Maintenance and Description Inspection Parts Wipe any stain of the display using a soft cloth slightly dampened with neutral detergent or Display alcoholic solvent.
  • Page 106 5 HG1P Adjusting the Brightness ● The brightness of the HG1P display can be adjusted on the Adjust Brightness Screen. Press the Adjust Brightness at the bottom of the Maintenance Screen. The Adjust Brightness Screen appears. Maintenance System Mode Device Monitor Adjust Brightness Press the <<...
  • Page 107 5 HG1P Adjusting the Touch Panel ● A gap may be caused in the operation accuracy of the touch panel by the secular distortion, etc. Adjust the touch panel according to the following procedure when there is a gap in the operation of the touch panel. Press the Main Menu on the Top Page in System Mode.
  • Page 108 5 HG1P 1-98 MICRO/I Hardware Manual...
  • Page 109: Expansion Modules

    The MICRO/I has an expansion interface which allows you to add input and output functionality by adding expansion modules. For the HG5G/4G/3G-V, HG4G/3G, up to four IDEC MICROSmart PLC expansion I/O modules may be installed. For the HG2G-V, HG2G-5F, up to two IDEC MICROSmart PLC expansion I/O modules may be installed.
  • Page 110: Applicable Expansion Modules

    HG2J-7U HG5G-V HG4G-V HG4G HG3G-V HG3G HG2G-V HG2G-5F HG2G-5T HG1G HG1P IDEC MicroSmart PLC Analog I/O modules that can be attached as expansion modules are shown below. ■ Analog Input Module Input Type Type Model No. Resistance Voltage Current Thermocouple...
  • Page 111 HG5G-V HG4G-V HG4G HG3G-V HG3G HG2G-V HG2G-5F HG2G-5T HG1G HG1P IDEC MicroSmart PLC Digital I/O module that can be attached as expansion modules are shown below. ■ Digital Input Modules YES: Supported, NO: Not supported Consumpti HG5G/ on Current Dimensions...
  • Page 112 1 Overview ■ Digital Output Modules YES: Supported, NO: Not supported Consumption Dimensions HG4G HG5G HG4G HG2G Current (mA) Type Model No. Terminal (L x W x H /3G/ (mm)) 2G-V 24 V 8 points/Relay Output FC4A-R081 90.0×23.5×70.0 16 points/Relay Output FC4A-R161 90.0×23.5×70.0 Removable Screw...
  • Page 113 1 Overview ■ Digital Combination I/O Modules YES: Supported, NO: Not supported Consumpti Dimensions HG5G/ on Current HG4G HG2G Type Model No. Terminal (L x W x H 4G/3G/ (mA) (mm)) 2G-V 24 V 4 points/DC Input, Removable Screw FC4A-M08BR1 90.0×23.5×70.0 4 points/Relay Output terminal block...
  • Page 114 1 Overview ■ Status Status Description Hexadecimal Binary 0x00 0000 0000 Normal Communication error (An error has occurred in the communication between MICRO/I 0x81 1000 0001 and an expansion module.) 0x82 1000 0010 Unknown device detected Device setting error (No device is connected or the connected device is different from 0x83 1000 0011 the setting of the project.)
  • Page 115: The Expansion Module Operation

    1 Overview 1.3 The Expansion Module Operation The Expansion modules can be controlled by switch parts, command parts and scripts. Processing priority should be determined based on the application. When the MICRO/I is switched from operation mode to another mode, the state of the output terminal of the expansion module is as follows.
  • Page 116 1 Overview Operation with priority on display processing ● When there are external inputs Control processing Expansion module input Start of scan Input 10 msec refresh Input 10 msec refresh External input Scan time Display processing 1 scan Input 10 msec refresh Input delay External...
  • Page 117 1 Overview Writing to the external outputs Control processing Expansion module output Start of scan Output 10 msec refresh Output 10 msec refresh Output Output External delay output (#Q, #D, LEY) Scan time Display processing 1 scan Output 10 msec refresh Output Output...
  • Page 118 1 Overview Operation of priority on control processing ● Execution Period Input delay External Input refresh input Input Starts processing the part at the top (#I, #D, LEX) I/O control Cyclic of screen Script Output Output refresh Execution External (#Q, #D, LEY) output Period Output...
  • Page 119 1 Overview ■ Output delay The min-to-max delay time for the Output (#Q, #D and LEY) to fire from the expansion module is 1 millisecond to 1 millisecond + the Execution Period. There will be maximum output delay if output is made to the expansion module immediately after the output refresh ends.
  • Page 120 1 Overview Operation Example Where, • Execution interval: 100 milliseconds • Input refresh: 1 millisecond • I/O control: 10 milliseconds • Output refresh: 1 millisecond Execution interval (100 msec) Input delay (5 to 105 msec) External Input refresh (1 msec) input Input Cyclic...
  • Page 121: Analog I/O Modules

    2 Analog I/O Modules Analog I/O Modules HG2J-7U HG5G-V HG4G-V HG4G HG3G-V HG3G HG2G-V HG2G-5F HG2G-5T HG1G HG1P Modules 2.1 Using Analog I/O Analog I/O modules are available that allow the MICRO/I to directly handle analog data such as voltage, current, and temperature.
  • Page 122 2 Analog I/O Modules Analog Input Type ● The following parameters are for configuring the analog inputs on the analog input modules and the mixed analog I/ O modules. YES: Supported, NO: Not supported FC6A- FC6A- FC6A- FC6A- FC6A- FC6A- FC6A- FC6A- J2C1...
  • Page 123 2 Analog I/O Modules ■ Signal Type The signal type that can be set differs according to the analog I/O module model. Select the analog I/O module that corresponds to the user application and set the signal type. The signal type is the type of analog input to measure. There are 24 signal types for the analog inputs, which are detailed as follows.
  • Page 124 2 Analog I/O Modules ■ Data Format The analog input value can be handled as the set data format. There are seven data formats for the analog inputs. YES: Supported, NO: Not supported FC6A- FC6A- FC6A- FC6A- FC6A- FC6A- FC6A- FC6A- J2C1 J4A1...
  • Page 125 2 Analog I/O Modules ■ Minimum and maximum values The values of Min. and Max. are determined by the set Signal Type and Data Format. The value is stored in the Data according to values of Min. and Max.. The minimum and maximum values that correspond to the signal type and data formats are as follows. Data Format Binary Optional...
  • Page 126 2 Analog I/O Modules ■ Filter The analog input is filtered so it reaches approximately 99% of the analog input in the set time. Rapid fluctuations in the analog input can be reduced by setting the filter, but increasing the filter slows down the tracking of fluctuations in the analog input.
  • Page 127 2 Analog I/O Modules ■ Sampling Time Analog values are converted to digital values at the interval of the sampling time. Depending on the analog I/O module, you may be able to change the sampling time setting. Type Signal Type Sample Time 0 to 10V DC 1 msec...
  • Page 128 2 Analog I/O Modules ■ Thermistor settings When NTC Thermistor is selected as Signal Type for the FC6A-J8CU1 or FC6A-J8CU4, the following parameters must be set. Parameter Description Range 0 to 65,535 The thermistor resistance in "T0" °C (Ω) -32,768 to 32,767 Temperature (°C) -32,768 to 32,767 Thermistor B constant...
  • Page 129 2 Analog I/O Modules Out of range error for Analog Input Value (Status: 5, 6) When the analog input value reaches or exceeds the following upper limit, the out of maximum range error occurs. When the analog input valuefalls below the following lower limit, the out of minimum range error occurs. Signal Type Lower Limit Value Upper Limit Value...
  • Page 130 2 Analog I/O Modules PTC Thermistor (Threshold) This section describes details on PTC thermistor (threshold). The value is stored in Data according to the resistance of the PTC thermistor and the values of Min. and Max.. The relationship between the resistance of the PTC thermistor, the values of Min. and Max., and Data is as follows. PTC thermistor resistance (Ω) 10,000 Max.
  • Page 131 2 Analog I/O Modules Analog Output Type ● The following parameters are for configuring the analog outputs on the analog output modules and the mixed analog I/O modules. YES: Supported, NO: Not supported FC6A-K2A1 FC6A-K4A1 FC6A-L06A1 FC6A-L03CN1 Parameter FC6A-K2A4 FC6A-K4A4 FC6A-L06A4 FC6A-L03CN4 Signal Type...
  • Page 132 2 Analog I/O Modules ■ Data Format The analog output value can be handled as the set data format. There are two data formats for the analog outputs. YES: Supported, NO: Not supported FC6A-K2A1 FC6A-K4A1 FC6A-L06A1 FC6A-L03CN1 Data Format FC6A-K2A4 FC6A-K4A4 FC6A-L06A4 FC6A-L03CN4...
  • Page 133 2 Analog I/O Modules Control Registers ● For the DR Allocation, configures the data register as the device to which each parameter of the analog I/O module is written. Multiple words are used starting from the configured data register. The number of words of data registers that are used varies based on the analog I/O module model.
  • Page 134: Device Allocation

    2 Analog I/O Modules 2.3 Device Allocation Analog Input Module ● Allocation of device address for the analog input module is shown below. For details about the parameter setting values, refer to “ Analog Input Parameter Setting Values” on page 2-27. FC6A- FC6A- FC6A-...
  • Page 135 2 Analog I/O Modules Analog Input Parameter Setting Values The parameter setting values are as follows. ■ Signal Type Setting Value Signal Type Unused 0 to 10V DC -10 to +10V DC 0 to 20mA DC 4 to 20mA DC Type K thermocouple Type J thermocouple Type R thermocouple...
  • Page 136 2 Analog I/O Modules ■ Filter Setting Value Filter 0 msec 50 msec 100 msec 150 msec … … 50,000 50,000 msec The setting value is rounded by 50. When 50,001 to 65,535 is stored for the setting value, the filter operates as the maximum value of 50,000 milliseconds.
  • Page 137 2 Analog I/O Modules Analog Output Parameter Setting Values The parameter setting values are as follows. ■ Signal Type Setting Value Signal Type Unused 0 to 10V DC -10 to +10V DC 0 to 20mA DC 4 to 20mA DC If the setting value is outside the range, a parameter setting error will occur.
  • Page 138: Digital I/O Modules

    3 Digital I/O Modules Digital I/O Modules HG2J-7U HG5G-V HG4G-V HG4G HG3G-V HG3G HG2G-V HG2G-5F HG2G-5T HG1G HG1P 3.1 Using Digital I/O Modules The inputs and outputs on the digital I/O modules are mapped to following device address locations within the MICRO/I.
  • Page 139: Chapter 3 Options

    Length: 5m HG9Z-XC275 PLC Connection Cable <Connector> Main unit: Parted Wire External device: Mini DIN 8-pin Connection cable for Serial interface (COM) (Compatible models: IDEC FC6A MICROSmart FC6A-C*****E only) FC6A-KC1C Length: 5m <Connector> Main unit: Parted Wire External device: RJ45...
  • Page 140: Hg5G/4G/3G/2G-V

    Extension Extension cable for attaching to USB interface (Mini-B) HG9Z-XCE21 Cable Length: 1m Connection cable for Serial interface (COM) (Compatible models: IDEC FC5A/4A MICROSmart) Length: 2.4m FC2A-KP1C <Connector> Main unit: Parted Wire External device: Mini DIN 8-pin Connection cable for Serial interface (COM)
  • Page 141 1 Optional items YES: Supported, NO: Not supported Name Type No. Description HG5G-V HG4G-V HG3G-V HG2G-V For HG5G-V HG9Z-5DFPN01 1 pce/pack For HG4G-V HG9Z-4DCPN02 2 pcs/pack Protective For HG3G-VA HG9Z-3DA2PN02 2 pcs/pack Sheet For HG3G-V8 HG9Z-3D8PN02 2 pcs/pack For HG2G-V HG9Z-2D5PN05 5 pcs/pack For HG2G-V...
  • Page 142: Hg4G/3G, Hg2G-5F

    USB Panel-Mount Extension Cable Extension cable for attaching to USB interface (Mini-B) HG9Z-XCE21 Length: 1m Connection cable for Serial interface (COM) (Compatible models: IDEC FC5A/4A MICROSmart) Length: 2.4m FC2A-KP1C <Connector> Main unit: Parted Wire External device: Mini DIN 8-pin Connection cable for Serial interface (COM)
  • Page 143 1 Optional items YES: Supported, NO: Not supported Name Type No. Description HG4G HG3G HG2G-5F To convert from D-sub 25-pin to 9-pin Connector (used when replacing from HG4F/3F/2F HG9Z-XCT11 Conversion Cable to HG4G/3G, HG2G-5F) Length: 16cm For HG4G HG9Z-4DCPN02 2 pcs/pack For HG3G-A HG9Z-3DA2PN02 2 pcs/pack...
  • Page 144: Hg2G-5T, Hg1G

    USB Panel-Mount Extension Cable Extension cable for attaching to USB interface (Mini-B) HG9Z-XCE21 Length: 1m Connection cable for Serial interface (COM) (Compatible models: IDEC FC5A/4A MICROSmart) Length: 2.4m FC2A-KP1C <Connector> Main unit: Parted Wire External device: Mini DIN 8-pin Connection cable for Serial interface (COM)
  • Page 145: Hg1P

    1 Optional items 1.5 HG1P Name Type No. Description USB cable to connect to a computer Length: 2m Maintenance Cable HG9Z-XCM42 <Connector> Main unit: USB Mini-B Computer: USB Type-A Communication Mode: RS422/485 or Ethernet Length: 3m HG9Z-XCP13 <Connector> Main unit: CA-19S1N128007S External device: D-sub 25-pin Male Connector Communication Mode: RS422/485 or Ethernet Length: 5m...
  • Page 146 1 Optional items External Dimensions ■ Hand Strap (HG9Z-PS4) Unit: mm Length Adjuster (Black) ■ Wall-Mounted Hook (HG9Z-PK3) Unit: mm 39.6 44.1 MICRO/I Hardware Manual...
  • Page 147: Replacement Parts

    2 Replacement Parts Replacement Parts 2.1 HG2J-7U Name Type No. Qty. Description Mounting Clip HG9Z-4K2PN04 For HG2J-7U Serial interface Removable terminal block 9-pin HG9Z-XT09P connector (Vertical type, Push-in type) 2.2 HG5G/4G/3G/2G-V YES: Supported, NO: Not supported Name Type No. Qty. Description HG5G-V HG4G-V HG3G-V HG2G-V HG9Z-4K2PN06...
  • Page 148: Hg2G-5T, Hg1G

    2 Replacement Parts 2.4 HG2G-5T, HG1G YES: Supported, NO: Not supported Name Type No. Qty. Description HG2G-5T HG1G HG9Z-4KPN04 For HG1G Mounting Clip SLD-K02PN10 For HG2G-5T Coin type lithium manganese dioxide Replacement Battery HG9Z-XR1 battery CR2032 Serial interface connector HG9Z-XT09V Vertical type USB Cable Lock Pin HG9Z-XU1PN05...
  • Page 149 4) The failure or defects and damages of the Products arise from the usage of the Product in the way that is not intended; or 5) The failure or defects and damages of the Products arise from the cause beyond IDEC’s control including, but not limited to, fire, earthquake, flood, lightning, other natural disasters, and acts of God; or 6) The failure or defects and damages of the Products arise from the relocation, transportation or drop after you purchase the Products;...

Table of Contents